A comparative analysis of the results of corneal astigmatism correction by toric IOL using various markup methods

Author:

Ioshin I. E.1,Murashev A. O.2,Demin A. N.3

Affiliation:

1. Clinical Hospital of the Office of the President’s Affairs

2. Kovrov Eye Clinic “Bio Absolut”

3. Vologda Eye Clinic “Vizus Absolut”

Abstract

Purpose: to analyze the results of corneal astigmatism correction by cataract surgery using two methods of marking the calculated toric IOL axis with Alpins vector analysis. Materials and methods. The retrospective study group included 212 patients (259 eyes) with cataracts and baseline corneal astigmatism from 0.75 to 8.25 D. The patients were implanted with two varieties of toric IOLs: Alcon Acrysof Toric (113 patients, 135 eyes) and Zeiss AT Torbi 709M (99 patients, 124 eyes). IOL parameters were calculated using an IOLMaster 500 (Carl Zeiss) optical biometer, the target refraction being emmetropy. The axis of toric IOL alignment was determined by online calculators provided by the producers. The patients were divided into two groups in accordance with the marking method: group 1 patients (149 eyes) were marked using by the authors’ techniques that used the angular scale of the slit lamp, while group 2 (110 eyes) was treated with Verion (Alcon) and Callisto Eye (Zeiss) navigation systems. The effectiveness of astigmatism correction was assessed using the Alpins vector analysis method. Results. After surgery, both groups showed a significant increase in uncorrected (UCVA) and best corrected visual acuity (BCVA). In group 1, one month after the operation, the UCVA was 0.67 ± 0.19, and the BCVA was 0.80 ± 0.17. In group 2, UCVA was 0.69 ± 0,07, and BCVA was 0.80 ± 0.49. The success index (IOS) was 0.14 in group 1 and 0.11 in group 2. The difference vector (DV) in the two groups was 0.37 and 0.31 D, respectively, suggesting highly precise astigmatism correction. The average error angle (AOfE) in group 1 was 3.29°, and in group 2 — 3.29°. The average value of the TIA vector was 2.69 ± 1.01 D along the axis of 87.3°, in group 1, while that of group 2 was 2.75 ± 1.09 D along the axis of 95.1°. The average values of the SIA vector were 2.32 ± 0.99 D along the axis of 870 in group 1 and — 2.44 ± 1.03 D along the axis of 99.6° in group 2. Conclusion. The authors’ markup method using the angular scale of the slit lamp yields high functional results of corneal astigmatism correction. The comparative vector analysis of the two study groups shows similar results in applying the authors’ type of markup and that of intraoperative navigation systems.

Publisher

Real Time, Ltd.

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3