Anatomical and optical parameters and aberrations of the optical system of the eye in anisometropic myopia

Author:

Neroev V. V.1ORCID,Tarutta E. P.1ORCID,Khodzhabekyan N. V.1ORCID,Khandzhian A. T.1ORCID,Harutyunyan S. G.1ORCID

Affiliation:

1. Helmholtz National Medical Research Center of Eye Diseases

Abstract

Purpose: to compare anatomical and optical parameters and aberrations of both eyes in patients with acquired and congenital anisometropic myopia.Material and methods. 22 patients (44 eyes) aged 18–35 (averagely, 25.2) with acquired and congenital anisometropic myopia were examined using the Galilei G6 optical eye system analyzer (Ziemer, Switzerland). The analysis of total, corneal and internal aberrations of the eye was carried out on an OPD-Scan III (Nidek) aberrometer.Results. In both groups with acquired and congenital anisometropic myopia, the axial length of the higher myopic eye was greater than that of the fellow eye. A greater asphericity and higher astigmatism of the cornea were revealed in higher myopic eyes of patients with congenital myopia as compared to acquired myopia. The total RMS HOA in congenital myopia was significantly greater in the higher myopic eye compared to the fellow eye (1.07 D and 0.68 D, respectively) and greater than in cases of acquired myopia. All HOA were greater in higher myopic eyes as compared to the fellow ones in cases of congenital myopia. In case of acquired myopia only the total coma appeared to be greater in the higher myopic eye. Corneal aberrations in acquired anisometropic myopia did not differ in the paired eyes. In case of congenital myopia, the total tilt was significantly greater in the higher myopic eye, and total coma and spherical aberration have lower values, even with a transition to negative ones (p < 0.05).Conclusion. The revealed differences of the wavefront of the eyes with anisometropic congenital and acquired myopia are rather a consequence of anatomical and optical differences (the axial length of the eyes and the topography of the cornea), than the cause of anisometropia.

Publisher

Real Time, Ltd.

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3