Acoustic density of the sclera of keratoconus eyes and its clinical significance

Author:

Tarutta E. P.1,Khandzhyan A. T.1,Kiseleva T. N.1,Milash S. V.1,Ivanova A. V.1,Guryanova O. V.1,Markosyan G. A.1,Bedretdinov A. N.1,Ramazanova K. A.1

Affiliation:

1. Helmholtz National Medical Research Center of Eye Diseases

Abstract

Purpose: to assess the biophysical properties of the sclera by measuring its acoustic density in keratoconus, highly myopic, and healthy eyes. Material and methods. We examined 34 patients (67 eyes) aged 15–45 with keratoconus of various stages, 15 patients (30 eyes) aged 17–28 with high myopia and 15 people (30 eyes) aged 28–37 without ophthalmic pathology. The acoustic density of the sclera (ADS) was measured on the Voluson Е8 ultrasound device (GE Healthcare, USA) in the posterior eye pole (ADS-1) and in the equatorial area (ADS-2). The axial length (AL) of the eye, corneal thickness (CT), anterior chamber depth (ACD), and lens thickness (LT) were determined using Galilei G6 (Ziemer Group, Switzerland). The vitreal chamber depth (VCD) was calculated according to the formula: VCD = AL – СT – ACD – LT. Results. In keratoconus patients, the average ADS-1 value was 242.5 ± 7.4 conventional units (CU), ADS-2 averaged 234.1 ± 12.1 CU, AL was 24.6±1.1 mm long, and VCD was 17.1 ± 0.4 mm. In high myopia group, the average value proved to be significantly lower: ADS-1 was 210.3 ± 15.7 CU, ADS-2 — 201.2 ± 11,2 CU, while AL and VCD were higher: resp. 27.0 ± 0.7 mm and 19.2 ± 0.5 mm (p < 0,05). In the control group (healthy eyes), ADS-1 was 247.5 ± 2.8 and ADS-2 was 238.1 ± 0.6 CU, which practically showed no difference to the keratoconus group (p > 0.05). AL was 23.7 ± 0.6 mm, and VCD was 16.0 ± 0.6 mm. An insignificant tendency toward ADS drop in keratoconus eyes with AL over 25.0 mm was observed. Probably, we are dealing here with a combination of keratoconus with axial myopia. Conclusion. The acoustic density of the sclera of keratoconus patients approaches the respective parameter of healthy eyes and is significantly higher than that of highly myopic eyes. The analysis of acoustic density of the sclera and vitreal chamber depth may be considered as a method of additional differential diagnostics of keratoconus and congenital myopia with high corneal refraction and astigmatism.

Publisher

Real Time, Ltd.

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3