Five-year prospective subsidence analysis of 100 cemented polished straight stems: A concise clinical and radiological follow-up observation

Author:

Madörin Kevin,Siepen Wolf,Manzoni Isabella,Stoffel Karl Kilian,Ilchmann Thomas,Clauss Martin

Abstract

Early subsidence (>1.5mm) has been shown to be an indicator for later aseptic loosening of cemented hip stems. For the cemented twinSys® stem we published excellent short-term results at 2 years. Midterm data for this stem are available from national registers (NZL, NL), however in all of these sources, clinical and radiological results are missing. Aim of our study was to analyse mid-term survival and radiological changes around the cemented twinSys®stem with special emphasis on subsidence using EBRA-FCA. We conducted a prospective clinical and radiological 5-year follow-up study of 100 consecutive hybrid total hip arthroplasties (THA) using a polished, cemented collarless straight stem (twinSys®, Mathys AG®Bettlach, Switzerland) with a cementless monobloc pressfit cup (RM pressfit®, Mathys AG® Bettlach, Switzerland). Median age at surgery was 79 (69 to 93) years. No patient was lost to follow-up. Survival rates were calculated using the Kaplan-Meier method. Clinical (Harris Hip Score [HHS]) and radiological (cementing quality, alignment, osteolysis, debonding and cortical atrophy) outcomes and an in-depth subsidence analysis using EBRA-FCA were performed. 22 patients died in the course of follow-up unrelated to surgery, 21 stems had an incomplete radiological follow-up. 2 stems were revised, both due to an infection. The survival rate for the stem at 5 years was 98.0% (95% CI 95.3-100%). The survival rate of the stem for revision due to aseptic loosening at 5 years was 100%. The HHS improved from 53 (14-86) points preoperatively to 90 (49-100) points 5 years after surgery. Osteolysis was found in 2 stems without clinical symptoms. In 49 out of 55 patients with a complete radiological follow-up, the EBRA-FCA analysis was possible and showed an average subsidence of 0.66 (95% CI 0.46 to 0.86) mm 5 years after surgery. 10 patients showed a subsidence >1 mm, 5 of which bigger than 1.5 mm. Subsidence was independent from radiological changes and cementing quality. The cemented twinSys® stem showed excellent clinical and radiological mid-term results at five years’ follow-up and seems to be a reliable implant.

Publisher

Open Medical Publishing

Subject

Orthopedics and Sports Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3