Deep sedation versus minimal sedation during endobronchial ultrasound transbronchial needle aspiration

Author:

Conte Sergio C.,Spagnol Giulia,Confalonieri Marco,Brizi Beatrice

Abstract

The sedation plays an important role in the endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) procedure. The sedation can be Minimal (anxiolysis), Moderate (conscious sedation) or Deep. The ACCP guidelines suggest that moderate or deep sedation (DS) is an acceptable approach. In fact, several studies compare moderate versus deep sedation, but no study has been carried out to compare deep sedation versus minimal. We carried out a retrospective study to compare the Deep versus Minimal sedation (MiS) in patients undergoing EBUS-TBNA.  The primary end point was the diagnostic accuracy. The secondary end points were adequacy and sensitivity. We evaluated the LN size sampling, procedural time, complications and patient tolerance. Thirty-six patients underwent EBUS-TBNA, 16 under DS and 20 under MiS. The overall diagnostic accuracy for correct diagnosis was 92.9% in DS group and 94.1% in MiS group (p=0.554). Sample adequacy, defined as the percentage of patients with a specific diagnosis by EBUS-TBNA, was 87.5% (14 of 16) and 85% (17 of 20) for the DS group and MiS group, respectively, (p=0.788); the sensitivity was 92.9% in the DS group (95% CI, 73-100%) and 92.9% in the MiS group (95% CI, 77-100%) (p=0.463). There were no major complications in either group. Minor complications were 4 in MiS and 1 in DS (p=0.355).  The patients in the MiS group recalled the procedure more often compared to the other group (p=0.041). The majority of the patients would agree to undergo the same procedure again in the future in both groups (p=0.766).  In our experience EBUS-TBNA performed under MiS has comparable accuracy, adequacy, sensitivity, complications and patient satisfaction to DS, even if the sample was small.  Future prospective multicenter studies are needed to confirm our results.

Publisher

PAGEPress Publications

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3