Flow-injection amperometric determination of adrenalin, melatonin, and Cortisol on the electrode modified by gold - palladium binary system and Nation film

Author:

Shaidarova L. G.1,Chelnokova I. A.1,Leksina Yu. A.1,Khairullina D. Yu.1,Budnikov H. C.1

Affiliation:

1. Kazan Federal University, Alexander Butlerov Institute of Chemistry

Abstract

Pharmaceuticals containing steroid hormones and their synthetic analogues are widely used in medicine. Accurate determination of the hormone content in biomedical objects is an urgent problem in modem analytical chemistry. A method for the selective and highly sensitive amperometric determination of adrenaline, melatonin, and cortisol in a flow-injection system has been developed. A scheme of a two-detector flow-injection system was proposed for the simultaneous determination of the adrenaline, melatonin, and cortisol content. Screen-printed carbon electrodes (SPE) with one or two working electrodes modified by gold-palladium binary system, which exhibited catalytic activity upon electrooxidation of organic compounds under study were used as detectors. A high sensitivity of the determination is attributed to the catalytic properties of the metal modifier: the transition between the metal and binary system leads to an increase in the catalytic current of hormones oxidation. The selectivity of the adrenaline determination in the presence of melatonin and cortisol is provided by the difference in the potentials of hormone oxidation at the developed electrode. For the selective determination of melatonin and cortisol the surface of the working electrode was modified by the Nation film. The potential difference between the oxidation peaks of adrenaline, melatonin and cortisol on the modified electrode was 300 mV. The proposed method was tested in analysis of real urine samples. The flow-injection scheme was supplemented with a dialyzer and a chromatographic mini-column to eliminate the interfering effect of electrophilic compounds. The linear logarithmic dependence of the analytical signal on the concentration of adrenaline, melatonin and cortisol is observed in the range from 5.0 x 10-10 to 5.0 x 10-3 M, from 5.0 x 10-11 to 5.0 x 10-3 M, and from 5.0 x 10-12 to 5.0 x 10-3 M, respectively. Amperometric determination of hormones in a flow-injection system leads to an increase in the productivity of analysis, decrease in the sample consumption and provides for automation of the process.

Publisher

TEST-ZL Publishing

Subject

Applied Mathematics,Mechanics of Materials,General Materials Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3