Optimization of sample preparation of mono- and bimetallic catalysts based on Sibunit carbon carrier for quantitative analysis by ICP-AES

Author:

Babenko A. V.1,Izmaylov R. R.1,Leont’eva N. N.1

Affiliation:

1. Center of New Chemical Technologies BIC, Boreskov Institute of Catalysis

Abstract

Composite materials like «Sibunit» are used as carriers for heterogeneous catalysts. These materials exhibit high mechanical strength, chemical purity, high resistance to aggressive environment, and controlled porous structure. The components of such catalysts are noble metals, and their combinations with oxides of some transition metals. An urgent task in their production is to control the content of the active component in the composition of catalysts. This characteristic affects the phase and electronic state of the metal, the structural and textural characteristics of the carbon carrier, and hence determines the activity and selectivity of catalysts during operation. Quantitative chemical analysis thus becomes one of the main methods for controlling the quality of catalysts. Different options for acid decomposition of mono- (Pd/C, Ru/C, Ga/C) and bimetallic (Pd-Ga/C, Pd-Zn/C, Pd-Ru/C, Pd-Ag/C) catalytic systems based on carbon carrier «Sibunit» are considered. The goal of this study is determination of the content of metals by inductively coupled plasma atomic emission spectrometry. The effect of the main operating parameters of the spectrometer on the intensity of sensitive and non-overlapping spectral lines of the elements being determined was studied. Optimal conditions for measuring the analytical signal were chosen. It is shown that for the studied bimetallic systems, with the exception of Pd-Ru/C, it is possible to choose a sample preparation option that allows simultaneous quantitative determination of two components from one sample. The developed method of quantitative analysis is characterized by rather high accuracy. The relative error of the element determination does not exceed 3 %, the relative standard deviation is not more than 5 %. The results of the study can be used to analyze catalysts of similar chemical composition by inductively coupled plasma atomic emission spectrometry.

Publisher

TEST-ZL Publishing

Subject

Condensed Matter Physics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3