Modified solid-contact sensors for determination of cefuroxime and cefalexin in medicines and oral fluid

Author:

Kulapina E. G.1,Dubasova A. E.1,Kulapina O. I.2

Affiliation:

1. Saratov State University, Department of Chemistry

2. Saratov State Medical University

Abstract

Cefuroxime, cefuroxime axetil and cefalexin are broad-spectrum pluripotential cephalosporin antibiotics. Their determination in various objects suggests using expensive spectroscopic, chromatographic, electrochemical equipment and organic solvents. Potentiometric sensors can provide rapid detection of cephalosporin antibiotics in a small sample volume without a preliminary sample preparation. The study is aimed at the developing of modified solid-contact potentiometric sensors for determination of cefuroxime and cefalexin in aqueous, biological media, and pharmaceuticals. The electroanalytical characteristics of unmodified and modified polyaniline and copper oxide nanoparticle sensors are evaluated. Tetradecylammonium(TDA) with a silver (I) – cefuroxime complex are used as the active membrane components, whereas polyaniline and copper oxide nanoparticles are used as modifiers. The main electroanalytic and operational characteristics of the studied sensors in aqueous solutions of antibiotics and against the background of oral fluid (LRP) are determined. The results of comparative evaluation of the electroanalytical properties of unmodified and modified solid-contact sensors in aqueous media of some â-lactam antibiotics and against the background of oral fluid are presented. The sensors based on Ag (Cefur)2TDA are characterized by a short response time: for modified polyaniline (PAN) and copper oxide nanoparticles within 5 – 10 sec, for unmodified — 10 – 20 sec. The linear range of the electrode functions for unmodified and modified sensors is 1 × 10–4 – 1 × 10–1 M, the detection limit is 7.4 × 10–5 M for unmodified and 6.3 × 10–5 M for modified sensors, respectively. The potential drift is 6 – 12 and 4 – 6 mV/day, service life is 1.5 and 2 months for unmodified and modified sensors, respectively. The modifiers stabilize the electrode potential, perform the function of the electron transfer mediator thus enhancing the electroanalytical characteristics of the sensors. The effect of the redox agents on the sensor properties is revealed: 1 × 10–3 – 1 × 10–4 MK 2Cr2O7 and FeCl3 solutions reduce the linearity intervals of the electrode functions, KI and Mohr’s salt do not affect the characteristics of the sensors in cefuroxime and cephalexin solutions. The coefficients of potentiometric selectivity of cefuroxime-selective sensors (modified with CuO nanoparticles) with respect to cefazolin, cefotaxime, and cefalexin are close to unity; Kijpot with respect to inorganic anions being part of the oral fluid (, Cl Br,I,HCO3 ,H PO 24 ,HPO4 2) are n × 10–2 – n × 10–3. This indicates the possibility of using sensors for detecting individual cephalosporin antibiotics or their total content in the presence of 100 – 1000 fold excesses of inorganic ions in medicinal and biological environments, small sample volumes, which is important when studying the pharmacokinetics of antibiotics and in determination of the maximum therapeutic dose when adjusting the treatment process.

Publisher

TEST-ZL Publishing

Subject

Condensed Matter Physics

Reference36 articles.

1. Belikov V G. Analysis of medicinal substances by photometric methods. Experience of domestic specialists / Ross. Khim. Zh. 2002. Vol. 45. N 4. P 14 19 [in Russian].

2. Kulapina O. I., Kulapina E. G. Antibacterial therapy. Modern methods of definition of antibiotiics in medicinal and biological environments. — Saratov: Saratovsky istochnik, 2014. P. 91 [in Russian].

3. Lugovskoy A. A., Bolshakov D. S., Nikeshina T. B. Development and validation of fluoroquinolone detection method in chicken eggs using high-performance liquid chromatography / Veterinariya Segodnya. 2016. N 1. P 30 36 [in Russian].

4. Singh S. P, Pundhir A., Ghosh S. Validation of an analytical methodology for determination of tetracyclines residues in honey by UPLC-MS/MS detection / Indian J. Nat. Prod. Resour. 2015. Vol. 6. N 4. P 293 298.

5. Rodriguez-Diaz C., Fernandez-Romero M., Aguilar-Caballos P. Chromatographic determination of flumeguine in food samplis by post-columderivatisation with terbium (III) / Anal. Chim. Acta. 2006. Vol. 578. P 220 226. DOI: 10.1016/ j.aca.2006.06.068.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3