Affiliation:
1. A. M. Butlerov Institute of Chemistry, Kazan (Volga region) Federal University
2. Chemical Department, M. V. Lomonosov Moscow State University
Abstract
Biosensor devices including hybrid nanostructures as modifiers of transducer surfaces meet current requirements for the methods of research and determination of drugs, including antidepressants. The features of amperometric monoamine oxidase biosensors based on printed carbon electrodes modified with nanocomposite compositions C60 / cobalt nanoparticles/amino derivative of polyether polyol of the second generation/chitosan nanocomposite structures used for the detection of tricyclic antidepressant amitriptyline are considered. The choice of the best modifier was made proceeding from the data of transmission electron microscopy, scanning electron microscopy, electrochemical impedance spectroscopy, and differential pulse voltammetry. When developing the biosensor, conditions for depositing the composite composition of cobalt nanoparticles/amino derivative of polyether polyol on the electrode surface were varied: electrochemical deposition, sequential layer-by-layer deposition, and deposition of the mixture. The peak of electrochemical oxidation of hydrogen peroxide, which is formed during the enzymatic reaction of serotonin oxidation under the action of monoamine oxidase was used as an analytical signal of the biosensor. The principle of the biosensor action is based on the inhibitory effect of amitriptyline on the catalytic activity of immobilized monoamine oxidase. The proper choice of a modifier and optimal working conditions provided the range of detectable concentrations of amitriptyline: 1 x 10-4 - 1 x 10-8 M, the lower limit of the determined content at a level of 5 x 10-9 M for monoamine oxidase biosensor. Comparison of the results on the amitriptyline content determination in the pharmaceutical preparation and urine obtained using the monoamine oxidase biosensor and polarization fluorescence immunoassay (dilution of the tracer 1:32, dilution of antibodies 1:128, the range of working concentrations 5 x 10 -8 — 5 x 10-9 M), well-proven in the quantitative determination of medicinal substance, confirmed the correctness of the results obtained.
Reference31 articles.
1. Medyantseva E. P, Brusnitsyn D. V, Varlamova R. M., et al. Determination of antidepressants using monoamine oxidase amperometric biosensors based on screen-printed graphite electrodes modified with multi-walled carbon nanotubes / Pharm. Chem. J. 2014. Vol. 48. N7.P 478 - 482. DOI: 10.1007/s11094-014-1135-2
2. Medyantseva E. P, Brusnitsyn D. V, Varlamova R. M., et al. Hyperbranched polyesterpolyols as components of amperometric monoamine oxidase biosensors based on electrodes modified with nanomaterials for determination of antidepressants / Russ. J. Appl. Chem. 2017. Vol. 90. N 1. P. 97 - 105. DOI: 10.1134/S1070427217010153
3. Medyantseva E. P, Brusnitsyn D. V, Varlamova R. M., et al. Monoamine oxidase biosensors based on silver nanoparticles and graphene oxide for the antidepressants determination / Butlerov. Soobshch. 2015. Vol. 41. N 3. P 36 - 43 [in Russian].
4. Zumpano R., Polli F., D’Agostino C., et al. Nanostructurebased electrochemical immunosensors as diagnostic tools / Electrochemistry. 2021. Vol. 2. N 1. P 10 - 28. DOI: 10.3390/electrochem2010002
5. Bastos-Soares E. A., Sousa R. M. O., Gomez A. F., et al. Single domain antibodies in the development of immunosensors for diagnostics / Int. J. Biol. Macromol. 2020. Vol. 165. P. 2244-2252. DOI: 10.1016/j.ijbiomac.2020.10.031
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献