Affiliation:
1. Institute of Automation and Electrometry, SB RAS; VMK-Optoelektronika, LLC
2. Institute of Automation and Electrometry, SB RAS; VMK-Optoelektronika, LLC; Novosibirsk State Technical University
Abstract
A review of publications regarding detection of non-metallic inclusions in metal alloys using optical emission spectrometry with single-spark spectrum registration is presented. The main advantage of the method - an extremely short time of measurement (~1 min) – makes it useful for the purposes of direct production control. A spark-induced impact on a non-metallic inclusion results in a sharp increase (flashes) in the intensities of spectral lines of the elements that comprise the inclusion because their content in the metal matrix is usually rather small. The intensity distribution of the spectral line of the element obtained from several thousand of single-spark spectra consists of two parts: i) the Gaussian function corresponding to the content of the element in a dissolved form, and ii) an asymmetric additive in the region of high intensity values ??attributed to inclusions. Their quantitative determination is based on the assumption that the intensity of the spectral line in the single-spark spectrum is proportional to the content of the element in the matter ablated by the spark. Thus, according to the calibration dependence constructed using samples with a certified total element content, it is possible not only to determine the proportions of the dissolved and undissolved element, but also the dimensions of the individual inclusions. However, determination of the sizes is limited to a range of 1 – 20 µm. Moreover, only Al-containing inclusions can be determined quantitatively nowadays. Difficulties occur both with elements hardly dissolved in steels (O, Ca, Mg, S), and with the elements which exhibit rather high content in the dissolved form (Si, Mn). It is also still impossible to determine carbides and nitrides in steels using C and N lines. The use of time-resolved spectrometry can reduce the detection limits for inclusions containing Si and, possibly, Mn. The use of the internal standard in determination of the inclusions can also lower the detection limits, but may distort the results. Substitution of photomultipliers by solid-state linear radiation detectors provided development of more reliable internal standard, based on the background value in the vicinity of the spectral line. Verification of the results is difficult in the lack of standard samples of composition of the inclusions. Future studies can expand the range of inclusions to be determined by this method.
Reference43 articles.
1. Grigorovich K. V. New Possibilities of Modern Methods for Determination of Gas-forming Impurities in Metals / Zavod. Lab. Diagn. Mater. 2007. Vol. 73. N 1. Part II. P. 23 – 34 [in Russian].
2. Imamura N. PITCON 76, Abstract Proceedings, paper 42, 1976.
3. Slickers K., Gruber J. Spectrometric Determination of Metallic and Non-Metallic Element Amounts in Steel / Stahl Eisen. 1984. Vol. 104. N 6. P. 293 – 298.
4. Falk H., Wintjens P. Statistical evaluation of single sparks / Spectrochim. Acta. Part B: Atomic Spectroscopy. 1998. Vol. 53. N 1. P. 49 – 62.
5. Rosefort M. et al. Determination of TiB~ 2 Inclusions in Al-Billets by Single Spark Emission Spectrometry / Light Metals-Warrendale-Proceedings. — TMS. 2008. Vol. 2008. P. 709.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献