Flow-injection determination of boric acid concentration with conductometric detection

Author:

Gursky V. S.1,Kharitonova E. Yu.1

Affiliation:

1. Alexandrov Research Institute of Technology

Abstract

The flow-injection determination of boric acid with conductometric detection in technological environments of the primary circuit of WWER-type nuclear power plant is described. The method consists in periodical dosing a fixed sample volume into the flow of the mannitol solution. As a of the Formation of an anionic boric acid complex with mannitol and equivalent amount of hydroxonium ions, results in an abrupt increase in the electrical conductivity, which is recorded by a conductometric detector. The hydraulic and measuring circuits of the analyzer are implemented using standard ionochromatographic equipment. It is shown than in the concentration range of the analyte 1 – 16 g/liter, the correcting additives of ammonium and potassium hydroxides do not interfere with the results of the analysis. To eliminate the interfering effect of correcting additives at low concentrations of boric acid (0.2 – 1.0 g/liter) we propose to use a Donnan dialysis through a cation exchange membrane. Optimal conditions of the analysis are specified and the metrological characteristics are determined. At a concentration of boric acid of 0.2 g/liter, the standard deviation does not exceed 2%.

Publisher

TEST-ZL Publishing

Subject

Condensed Matter Physics

Reference6 articles.

1. Krokhin O. V., Pirogov A. V., Obrezkov O. N., Shpigun O. A. Flow-injection determination of boric acid / Zh. Anal. Khimii. 1992. Vol. 47. N 5. P. 768 – 770 [in Russian].

2. Sangita D., Kumar B., Malti P. K. Determination of Boron by Flow Injection Analysis Using a Conductivity Detector / Anal. Chem. 1999. Vol. 71. P. 2552 – 2553.

3. Ananthanarayanan R., Sahoo P., Murali N. Digital conductometry for determination of boron in light water and heavy water at trace levels. / Indian J. Chem. Technol. 2012. Vol. 19(4). P. 278 – 288.

4. Tyapkov V. F., Sharafutdinov R. B. Current state, main problems and directions of improvement of water-chemical mode of nuclear power plants / Vestn. Gosatomnadz. Rossii. 2003. N 4. P. 8 – 19 [in Russian].

5. Gursky V. S., Voronina N. V., Timofeev S. V. Application of capillary suppressor in a two-column anion chromatography / Zavod. Labor. Diagn. Mater. 1996. Vol. 62. N 5. P. 15 – 18.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The choice of methods for lithium and boron determination in lithium-boron alloys;Industrial laboratory. Diagnostics of materials;2023-01-21

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3