Data on pore size distribution in solids are obtained by pycnometric density-based methods for measuring the pore structure of materials. The results of measuring open porosity by weighing a dry sample followed by evacuation and saturation with distilled water at atmospheric pressure, impregnation with water under pressure using a hydrostat and mercury porosimetry are presented. The samples of porous nickel obtained using powder technology by sintering of the compacts from mixtures of nickel nanopowder with powder ammonium bicarbonate NH4HCO3 (a blowing agent), the volume fractions of which were 80 and 20%, respectively, were studied. A powder blowing agent with a particle size of 63 – 125, 140 – 200, and 250 – 315 μm was used. A theoretical estimation of the pore size available for the penetration of the impregnating liquid was carried out for three methods used for the determination of open porosity. It is shown that upon water saturation after evacuation the liquid can penetrate only into pores larger than 3 μm. Moreover, in porous structures with a large fraction of submicron pores, the actual values of the open porosity are significantly underestimated when using the method of saturation with distilled water after evacuation. The higher the fraction of fine pores in the material, the lower the open porosity value. The difference between the open porosity values determined by methods of water impregnation using a hydrostat and mercury porosimetry was negligible. It has been established that among three considered methods for measuring open porosity, only the method of saturation with distilled water after evacuation cannot be used in analysis of structures with submicron pores. The results obtained can be used to develop porous functional materials and products with a given porosity structure.

Publisher

TEST-ZL Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3