Analysis of the Rate of Re-planning in Spot-Scanning Proton Therapy

Author:

Hu Yue-Houng1,Harper Riley H.2,Deiter Noelle C.3,Evans Jaden D.34,Mahajan Anita3,Kruse Jon J.1,Mundy Daniel W.1

Affiliation:

1. 1 Department of Radiation Oncology, Division of Medical Physics, Mayo Clinic, Rochester, MN, USA

2. 2 College of Science and Engineering, University of Minnesota, Minneapolis, MN, USA

3. 3 Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA

4. 4 Department of Radiation Oncology and Precision Genomics, Intermountain Cancer Center, Ogden, UT, USA

Abstract

Abstract Purpose Finite proton range affords improved dose conformality of radiation therapy when patient regions-of-interest geometries are well characterized. Substantial changes in patient anatomy necessitate re-planning (RP) to maintain effective, safe treatment. Regularly planned verification scanning (VS) is performed to ensure consistent treatment quality. Substantial resources, however, are required to conduct an effective proton plan verification program, which includes but is not limited to, additional computed tomography (CT) scanner time and dedicated personnel: radiation therapists, medical physicists, physicians, and medical dosimetrists. Materials and Methods Verification scans (VSs) and re-plans (RPs) of 711 patients treated with proton therapy between June 2015 and June 2018 were studied. All treatment RP was performed with the intent to maintain original plan integrity and coverage. The treatments were classified by anatomic site: brain, craniospinal, bone, spine, head and neck (H&N), lung or chest, breast, prostate, rectum, anus, pelvis, esophagus, liver, abdomen, and extremity. Within each group, the dates of initial simulation scan, number of VSs, number of fractions completed at the time of VS, and the frequency of RP were collected. Data were analyzed in terms of rate of RP and individual likelihood of RP. Results A total of 2196 VSs and 201 RPs were performed across all treatment sites. H&N and lung or chest disease sites represented the largest proportion of plan modifications in terms of rate of re-plan (RoR: 54% and 58%, respectively) and individual likelihood of RP on a per patient basis (likelihood of RP [RP%]: 46% and 39%, respectively). These sites required RP beyond 4 weeks of treatment, suggesting continued benefit for frequent, periodic VS. Disease sites in the lower pelvis demonstrated a low yield for RP per VS (0.01-0.02), suggesting that decreasing VS frequency, particularly late in treatment, may be reasonable. Conclusions A large degree of variation in RoR and individual RP% was observed between anatomic treatment sites. The present retrospective analysis provides data to help develop anatomic site–based VS protocols.

Publisher

International Journal of Particle Therapy

Subject

Radiology, Nuclear Medicine and imaging,Atomic and Molecular Physics, and Optics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3