The Advantage of Proton Therapy in Hypothalamic-Pituitary Axis and Hippocampus Avoidance for Children with Medulloblastoma

Author:

Aljabab Saif1,Rana Shushan2,Maes Shadonna3,O'Ryan-Blair Avril3,Castro Jackie3,Zheng Jack4,Halasz Lia M.2,Taddei Phillip J.235

Affiliation:

1. Radiation Oncology Department, King Saud University, Riyadh, Saudi Arabia

2. Radiation Oncology Department, University of Washington School of Medicine, Seattle, WA, USA

3. Seattle Cancer Care Alliance Proton Therapy Center, Seattle, WA, USA

4. Radiation Medicine Program, the Ottawa Hospital Cancer Centre, Ottawa, ON, Canada

5. Department of Radiation Oncology, Mayo Clinic, Rochester, MN, USA

Abstract

Abstract Purpose Craniospinal irradiation (CSI) improves clinical outcomes at the cost of long-term neuroendocrine and cognitive sequelae. The purpose of this pilot study was to determine whether hypothalamic-pituitary axis (HPA) and hippocampus avoidance (HPA-HA) with intensity-modulated proton therapy (IMPT) can potentially reduce this morbidity compared with standard x-ray CSI. Materials and Methods We retrospectively evaluated 10 patients with medulloblastoma (mean, 7 years; range, 4-14 years). Target volumes and organs at risk were delineated as per our local protocol and the ACNS0331 atlas. An experienced neuroradiologist verified the HPA and hippocampus contours. The primary objective was CSI and boost clinical target volume (CTV) covering 95% of the volume (D95) > 99% coverage with robustness. Described proton therapy doses in grays are prescribed using a biological effectiveness relative to photon therapy of 1.1. The combined prescribed dose in the boost target was 54 Gy. Secondary objectives included the HPA and hippocampus composite average dose (Dmean ≤ 18 Gy). For each patient, volumetric modulated arc radiotherapy (VMAT) and tomotherapy (TOMO) plans existed previously, and a new plan was generated with 3 cranial and 1 or 2 spinal beams for pencil-beam scanning delivery. Statistical comparison was performed with 1-way analysis of variance. Results Compared with standard CSI, HPA-HA CSI had statistically significant decreases in the composite doses received by the HPA (32.2 versus 17.9 Gy; P < .001) and hippocampi (39.8 versus 22.8 Gy; P < .001). The composite HPA Dmean was lower in IMPT plans (17.9 Gy) compared with that of VMAT (21.8 Gy) and TOMO (21.2 Gy) plans (P = .05). Hippocampi composite Dmean was also lower in IMPT plans (21 Gy) compared with that of VMAT (27.5 Gy) and TOMO (27.2 Gy) plans (P = .02). The IMPT CTV D95 coverage was lower in IMPT plans (52.8 Gy) compared with that of VMAT (54.6 Gy) and TOMO (54.6 Gy) plans (P < .001) The spared mean volume was only 1.35% (19.8 cm3) of the whole-brain CTV volume (1476 cm3). Conclusion We found that IMPT has the strong potential to reduce the dose to the HPA and hippocampus, compared with standard x-ray CSI while maintaining target coverage. A prospective clinical trial is required to establish the safety, efficacy, and toxicity of this novel CSI approach.

Publisher

International Journal of Particle Therapy

Subject

Radiology, Nuclear Medicine and imaging,Atomic and Molecular Physics, and Optics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370