Monte Carlo Simulations of Neutron Ambient Dose Equivalent in a Novel Proton Therapy Facility Design

Author:

Titt Uwe1,Pera Enzo1,Gillin Michael T.1

Affiliation:

1. University of Texas, M. D. Anderson Cancer Center, Houston, TX, USA

Abstract

Abstract Purpose The neutron shielding properties of the concrete structures of a proposed proton therapy facility were evaluated with help of the Monte Carlo technique. The planned facility's design omits the typical maze-structured entrances to the treatment rooms to facilitate more efficient access and, instead, proposes the use of massive concrete/steel doors. Furthermore, straight conduits in the treatment room walls were used in the design of the facility, necessitating a detailed investigation of the neutron radiation outside the rooms to determine if the design can be applied without violating existing radiation protection regulations. This study was performed to investigate whether the operation of a proton therapy unit using such a facility design will be in compliance with radiation protection requirements. Methods A detailed model of the planned proton therapy expansion project of the University of Texas, M. D. Anderson Cancer Center in Houston, Texas, was produced to simulate secondary neutron production from clinical proton beams using the MCNPX Monte Carlo radiation transport code. Neutron spectral fluences were collected at locations of interest and converted to ambient dose equivalents using an in-house code based on fluence to dose-conversion factors provided by the International Commission on Radiological Protection. Results and Conclusions At all investigated locations of interest, the ambient dose equivalent values were below the occupational dose limits and the dose limits for individual members of the public. The impact of straight conduits was negligible because their location and orientation were such that no line of sight to the neutron sources (ie, the isocenter locations) was established. Finally, the treatment room doors were specially designed to provide spatial efficiency and, compared with traditional maze designs, showed that while it would be possible to achieve a lower neutron ambient dose equivalent with a maze, the increased spatial (and financial) requirements may offset this advantage.

Publisher

International Journal of Particle Therapy

Subject

Radiology Nuclear Medicine and imaging,Atomic and Molecular Physics, and Optics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3