Techniques for Treating Bilateral Breast Cancer Patients Using Pencil Beam Scanning Technology

Author:

Vyfhuis Melissa A. L.12,Zhu Mingyao1,Agyepong Benjamin1,Nichols Elizabeth M.12

Affiliation:

1. Department of Radiation Oncology, University of Maryland Medical Center, Baltimore, MD, USA

2. University of Maryland School of Medicine, Baltimore, MD, USA

Abstract

Abstract Purpose: Patients with bilateral breast cancer (BBC), who require postmastectomy radiation therapy or radiation as part of breast conservation treatment, present a unique technical challenge. Even with modern techniques, such as intensity modulated radiation therapy or volumetric modulated arc therapy (VMAT), adequate target coverage is rarely achieved without the expense of increased integral dose to important organs at risk (OARs), such as the heart and lungs. Therefore, we present several BBC techniques and a treatment algorithm using intensity-modulated proton therapy (IMPT) for patients treated at our center. Materials and Methods: We describe 3 different BBC treatment techniques using IMPT on patients treated at our center, with comparison VMAT plans to demonstrate the dosimetric benefit of proton therapy in these patients. Following RADCOMP (Radiation Therapy Oncology Group, Philadelphia, Pennsylvania) guidelines, a single physician approved all target volumes and OARs. Plans were designed so that ≥ 95% of the prescribed dose covered ≥ 95% of all targets. Parameters for dosimetric volume histograms for the clinical targets and OARs are reported for the 2 radiation methods. Results: All methods demonstrated acceptable target coverage with 95% of the prescription planning target volume reaching a mean (± SD) of 98.0% (± 0.87%) and 97.5% (± 2.39%), for VMAT and IMPT plans, respectively. Conformity and homogeneity were also similar between the 2 techniques. Proton therapy provided observed improvements in mean heart dose (average heart mean [SD], 9.98 Gy [± 0.87 Gy] versus 2.12 Gy [± 0.96 Gy]) and total lung 5% prescription dose (V5; mean [SD] total lung V5, 97.9% [± 2.84%]), compared with 39.8% [± 9.39%]). All IMPT methods spared critical OARs; however, the single, 0° anterior-posterior plan allowed for the shortest treatment time. Conclusion: Both VMAT and all 3 IMPT techniques provided excellent target coverage in patients with BBC; however, proton therapy was superior in decreasing the dose to OARs. A single-field optimization approach should be the IMPT method of choice when feasible.

Publisher

International Journal of Particle Therapy

Subject

Radiology, Nuclear Medicine and imaging,Atomic and Molecular Physics, and Optics

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Proton Beam Therapy for Breast Cancer;Critical Reviews™ in Oncogenesis;2024

2. GALIP: Generative Adversarial CLIPs for Text-to-Image Synthesis;2023 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR);2023-06

3. Proton Therapy for Bilateral Breast Cancer Maximizes Normal-Tissue Sparing;International Journal of Particle Therapy;2023-03

4. Synchronous bilateral chest wall irradiation with regional nodal irradiation: A literature review of techniques and a case study;Physica Medica;2022-09

5. Text-to-Image Synthesis based on Object-Guided Joint-Decoding Transformer;2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR);2022-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3