Hydrogel Spacer Reduces Rectal Dose during Proton Therapy for Prostate Cancer: A Dosimetric Analysis

Author:

Polamraju Praveen1,Bagley Alexander F.2,Williamson Tyler2,Zhu X. Ronald3,Frank Steven J.2

Affiliation:

1. University of Texas Medical Branch at Galveston School of Medicine, Galveston, TX, USA

2. Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, USA

3. Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, TX, USA

Abstract

Abstract Purpose: Proton therapy for prostate cancer may reduce bowel dose and risk of bowel symptoms relative to photon-based methods. Here, we determined the effect of using a biodegradable, injectable hydrogel spacer on rectal dose on plans for treating prostate cancer with intensity-modulated proton therapy (IMPT) or passive scattering proton therapy (PSPT). Materials and Methods: Pairs of IMPT and PSPT plans for 9 patients were created from fused computed tomography/magnetic resonance imaging scans obtained before and after spacer injection. Calculated values of rectal V40, V60, V70, V80, and maximum dose (Dmax) were compared with Wilcoxon signed rank tests. Displacements at the base (BP), midgland (MP), and apex (AP) of the prostate relative to the anterior rectal wall with the spacer in place were averaged for each patient and correlated with V70 by using linear regression models. Results: The presence of a spacer reduced all dosimetric parameters for both PSPT and IMPT, with the greatest difference in V70, which was 81.1% lower for PSPT-with-spacer than for IMPT-without-spacer. Median displacements at BP, MP, and AP were 12 mm (range 7-19), 2 mm (range 0-4), and 1 mm (range 0-5) without the spacer and 19 mm (range 12-23), 10 mm (range 8-16), and 7 mm (range 2-12) with the spacer. Modest linear trends were noted between rectal V70 and displacement for IMPT-with-spacer and PSPT-with-spacer. When displacement was ≥8 mm, V70 was ≤5.1% for IMPT-with-spacer and PSPT-with-spacer. Conclusion: Use of biodegradable hydrogel spacers for prostate cancer treatment provides a significant reduction of radiation dose to the rectum with proton therapy. Significant reductions in rectal dose occurred in both PSPT and IMPT plans, with the greatest reduction for IMPT-with-spacer relative to PSPT alone. Prospective studies are ongoing to assess the clinical impact of reducing rectal dose with hydrogel spacers.

Publisher

International Journal of Particle Therapy

Subject

Radiology, Nuclear Medicine and imaging,Atomic and Molecular Physics, and Optics

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3