Feasibility study of TPC detector at high luminosity Z pole on the circular collider

Author:

Yuan Zhiyang12,Qi Huirong12,Chang Yue123,Zhang Jian12,Wu Ye12,Zhang Hongyu12,Chen Yuanbo12,Cai Yiming14,Li Yulan14,Deng Zhi14,Gong Hui14

Affiliation:

1. State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing 100049, China

2. University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China

3. Nankai University, 94 Weijin Road, Nankai District, Tianjin 300071, China

4. Department of Engineering Physics, Tsinghua University, Hai Dian District, Beijing 100084, China

Abstract

With the development of the circular collider, it is necessary to make accurate physics experimental measurements of particle properties at higher luminosity [Formula: see text] pole. Micro-pattern gaseous detectors (MPGDs), which contain gaseous electron multiplier (GEM) and micro-mesh gaseous structures (Micromegas), have excellent potential for development as the readout devices of the time projection chamber (TPC) tracker detector. To meet the updated physics requirements of the high luminosity [Formula: see text] from the preliminary concept design report (preCDR) to concept design report (CDR) at the circular electron–positron collider (CEPC). In this paper, the space charge distortion of the TPC detector is simulated with the CEPC beam structure. Using the multi-physics simulation software package, the distribution of ion estimated by Geant4 is used as the input for the differential equation, and the relationship between the ion density distribution and electric field in the detector chamber is simulated. These simulation results show that the maximum deviation for Higgs [Formula: see text] meets the performance requirements in CEPC TPC detector at the high luminosity [Formula: see text] pole, while it is still a considerable challenge for [Formula: see text] pole, with the maximum deviation [Formula: see text]. According to the previous developments, the cascaded structure of GEM and Micromegas detector has been measured. The new considerations of the detector’s requirements were given, the gain needs to be reached to about 2000 with IBF[Formula: see text]Gain under 0.1, and IBF means the ions back flow ratio of the detector. The pixel TPC is a potential option to replace the traditional MPGDs with the low gain, low occupancy, and outstanding pattern recognition. Finally, some update parameters and experiments results were compared.

Funder

National Natural Science Foundation of China

National Key Programme for S&T Research and Development

Publisher

World Scientific Pub Co Pte Lt

Subject

Astronomy and Astrophysics,Nuclear and High Energy Physics,Atomic and Molecular Physics, and Optics

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. High Precision Pad and Pixelated TPC Technology Development for Electron Positron Collider;2022 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC);2022-11-05

2. Progress of TPC Detection Technology Development for ILD Detector at e+ e Collider;2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC);2021-10-16