Abstract

Background: Specific treatment of the volar marginal rim fragment of distal radius fractures avoids occurance of volar radiocarpal dislocation. Although several fixation systems are available to capture this fragment, adequately maintaining internal fixation is difficult. We present our experience of the first 10 cases using the 2.4 mm variable angle LCP volar rim distal radius plate (Depuy Synthes®, West Chester, US), a low-profile volar rim-contouring plate designed for distal plate positioning and stable buttressing of the volar marginal fragment. Methods: Follow-up patient satisfaction, range of motion, grips strength, functional scoring with the QuickDASH and residual pain with a numeric rating scale were assessed. Radiological evaluation consisted in evaluating fracture consolidation, ulnar variance, volar angulation and maintenance of the volar rim fixation. Results: The female to male ratio was 5:5 and the mean age was 52.2 (range, 17–80) years. The mean follow-up period was 11 (range, 5–19) months postoperatively. Patient satisfaction was high. The mean total flexion/extension range was 144° (range, 100–180°) compared to the contralateral uninjured side 160° (range, 95–180°). The mean total pronation/supination range was 153° (range, 140–180°) compared to the contralateral uninjured side 170° (range, 155–180°). Mean grip strength was 14 kg (range, 9–22), compared to the contralateral uninjured side 20 kg (range, 12–25 kg). Mean pre-injury level activity QuickDASH was 23 (range, 0–34.1), while post-recovery QuickDASH was 25 (range 0–43.2). Residual pain was 1.5 on the visual numerical pain rating scale. Radiological evaluation revealed in all cases fracture consolidation, satisfactory reconstruction of ulnar variance, volar angulation and volar rim. We encountered no flexor tendon complications, although plate removal was systematically performed after fracture consolidation. Conclusions: The 2.4 mm variable angle LCP volar rim distal radius plates is a valid treatment option for treating the volar marginal fragment in distal radius fractures.

Publisher

World Scientific Pub Co Pte Lt

Subject

General Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3