Abstract
In the present study, performance evaluation of three different configurations of absorption heat transformer (AHT) is carried out by supplying the waste heat of same mass and same temperature; and exergy analysis is done using both the classical and modified Gouy–Stodola equation. For this a mathematical model is developed for all the three arrangements in Engineering Equation Solver. Water–lithium bromide is used as a working pair. The results of exergy destruction with classical and modified Gouy–Stodola equation are compared for different systems. Further various operating parameters are varied to predict the performance of the systems on the basis of second law analysis. The result showed that the amount of hot fluid produced in absorber is more for system 3 as compared to other configurations. The irreversibility calculated by the modified approach comes out to be 25.78%, 23.60%, and 23.45% more than the exergy destruction obtained by the classical approach in the three cases, respectively. Thus, there is a need to employ the modified approach of Gouy–Stodola equation for calculating the real irreversibility which helps in predicting the scope of improvement and the performance of the system more accurately.
Publisher
Springer Science and Business Media LLC
Subject
Fluid Flow and Transfer Processes,Renewable Energy, Sustainability and the Environment,Control and Systems Engineering
Cited by
4 articles.
订阅此论文施引文献