Nonrigid Registration of Pre-Procedural MRI and Intra-Procedural CT in CT-Guided Cryoablation of Lung Tumors to Improve Lung Tumor Conspicuity

Author:

Hata Nobuhiko1ORCID,Tatli Servet2,Yamada Atsushi1,Olubiyi Olutayo3,Silverman Stuart G.2

Affiliation:

1. Surgical Navigation and Robotics Laboratory, Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02115, USA

2. Division of Abdominal Imaging and Intervention, Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02115, USA

3. Department of Neurosurgery, Brigham and Women’s Hospital and Harvard Medical School, 75 Francis St, Boston, MA 02115, USA

Abstract

To improve lung tumor conspicuity during CT-guided cryoablations, we used nonrigid image registrations to fuse pre-procedural MR images and intra-procedural CT images and determined which set of CT images taken at planning, targeting, and monitoring phases of the procedure provided the most accurate and fastest registrations. In 10 percutaneous CT-guided cryoablation procedures, MR images were registered with intra-procedural CT images using a nonrigid registration technique using an intensity-based approach with affine and B-Spline transformations. The time to complete the registration as well as the accuracy of the registration defined by Target Registration Error (TRE), Dice Similarity Coefficient (DSC), and Hausdorff Distance (HD) were measured to assess the performance of the registration. The least significant difference (LSD) method was used as a post-hoc analysis for comparing time and accuracy among planning, targeting, and monitoring phases. The mean TRE of the registration ranged from 6.26 (planning) to 10.31 (monitoring) mm. The mean DSC ranged from 83.86 (monitoring) to 89.22 (planning). The mean HD values ranged from 7.74 (targeting) to 12.20 (monitoring). Mean registration time ranged from 68.67 (monitoring) to 92.02 (planning) s. Using HD, registrations in either the planning or targeting phase were more accurate than in the monitoring phase. The registration was faster using monitoring images than using planning images. Nonrigid registration techniques can be used to fuse pre-procedural MR images with intra-procedural CT images with varying performance depending on the CT images taken at the different phases of the procedure. Therefore, caution should be taken in setting expectations on accuracies and speeds of registration depending on the phases of the CT-guided ablation procedures.

Funder

National Cancer Institute (US)

National Institute of Biomedical Imaging and Bioengineering (US)

Publisher

World Scientific Pub Co Pte Lt

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3