A new approach for detecting sudden hypotension in hemodialysis by using dual-channel optical system

Author:

Mohamad Amin Younessi Heravi1,Ebrahim Golmakani2,Sima Joharinia3

Affiliation:

1. Department of Basic Sciences, North Khorasan University of Medical Sciences, Bojnurd, Iran

2. Department of Anesthesiology and Critical Care, Mashhad University of Medical Sciences, Mashhad, Iran

3. Department of Electrical Engineering, Young Researchers and Elite Club, Bojnourd Branch, Islamic Azad University, Bojnourd, Iran

Abstract

Dialysis hypotension is one of the most prevalence symptoms of dialysis and occurs in 40% of treatment sessions. Detection and prediction of hypotension is important for the well-being of the patient and for optimizing treatment. The aim of this study was to construct optical system to monitor blood pressure (BP) continuously and without cuff in hemodialysis based on pulse transit time (PTT) method. To measure the BP changes, dual-channel optical system were developed. In this study, individuals were classified into two groups of normal and hemodialysis. In both groups, BP and consequently PTT were earned three times in different positions. After the initial calibration, the regression equation was drawn for each subject. In normal group, each subject was placed in the supine position and BP was measured both by designed system and sphygmomanometer cuff. During BP measurements, in addition to BP, blood pressure decline was also monitored by optical system. For hemodialysis group, the same measurement setup was adopted. In both groups, the error between cuff method and PTT was calculated. Correlation coefficients for BPcuff vs BPPTT were calculated and Bland–Altman plot was performed for the normal and hemodialysis groups. In this study 16 subjects participated. The results for normal group showed that maximum difference between cuff method and the present method was 14[Formula: see text]mmHg and for dialysis group was 16[Formula: see text]mmHg. Bland–Altman plot in normal group revealed limits of agreement from [Formula: see text]13.98 to 13.18[Formula: see text]mmHg. Considering hemodialysis group, limits of agreement were from [Formula: see text]15.94 to 13.88[Formula: see text]mmHg. The correlation coefficient was 0.74 for normal group and was 0.72 for hemodialysis group. The proposed system can monitor BP continuously and diagnose sudden hypotension. So it can be recommended as a useful method to indicate hypotension and can be used for dialysis unit.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering,Atomic and Molecular Physics, and Optics,Medicine (miscellaneous),Electronic, Optical and Magnetic Materials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3