Diffuse transmitted spectroscopy in conjunction with spectral peak averaging as a potential tool for noninvasive creatinine screening

Author:

Barnea (Burbea) Zvi Hai12,Zimlichman Shmuel3,Abookasis David3

Affiliation:

1. Nephrology Department, Edith Wolfson Hospital, Holon 5822012, Israel

2. Sackler Faculty of Medicine, Tel Aviv University, P. O. Box 39040, Tel Aviv 6997801, Israel

3. Department of Electrical and Electronics Engineering, Ariel University, Ariel 4070000, Israel

Abstract

Creatinine (Cr) is a biochemical waste molecule generated from muscle metabolism and primarily cleared from the bloodstream by the kidneys. If kidney function declines, Cr levels in the blood tend to increase. Therefore, Cr serves as an indicator of kidney function. In this work, we present a simple method for the rapid screening for impaired renal function based on the subject’s Cr concentration. In our setup, broadband white light is delivered to a finger clamp through a fiber-optic cable to illuminate the patient’s finger. The light is transmitted through the finger and collected by a second optical fiber coupled to a visible–near-infrared (VisNIR) spectrometer which covers the spectral range from 400[Formula: see text]nm to 1100[Formula: see text]nm. During the calibration process, the transmitted spectra acquired from 60 patients were measured. An average was calculated using the peak level of the transmitted, diffused intensity at three different wavelengths to create a “Cr intensity index”. Patients were divided into five groups according to their Cr concentration levels, ranging from 1[Formula: see text]mg/dL to 13[Formula: see text]mg/dL. Our observations indicated that each group featured a unique spectral fingerprint. Next, we tested the index on 20 patients not included in the calibration procedure (unknown samples). We were able to classify patients into groups according to their Cr level with moderate prediction accuracy ([Formula: see text]) and mean screening error of up to 16%. Future efforts will evaluate the accuracy of this approach with larger patient populations representing a broad range of Cr concentration. Still, this preliminary work is an essential step toward developing this useful noninvasive Cr screening platform using NIR light spectroscopy.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering,Atomic and Molecular Physics, and Optics,Medicine (miscellaneous),Electronic, Optical and Magnetic Materials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3