ZERNIKE ASTIGMATISM AND VISUAL PERFORMANCE IN MYOPIC EYES BY RIGID GAS PERMEABLE CONTACT LENSES WEAR

Author:

BAO JINHUA1,MAO XINJIE1,WANG HAIRONG1,HE JI C.12,LU FAN1

Affiliation:

1. School of Optometry and Ophthalmology, Wenzhou Medical College, Wenzhou, Zhejiang, P. R. China

2. New England College of Optometry, Boston, Massachusetts, USA

Abstract

Purpose: To investigate the effects of rigid-gas-permeable contact lens (RGP-CL) wear on Zernike astigmatism and visual performance in myopic eyes. Methods: A wavefront sensor was used to evaluate Zernike astigmatism for 21 eyes with minimum astigmatism and 18 eyes with moderate astigmatism under three different modes of refractive correction: the RGP-CL, spectacle lens correcting spherical equivalent (SL) and spectacle lens fully correcting spherical error and astigmatism (fSL). Contrast visual acuity was assessed with a VA tester at four contrast levels and two luminance backgrounds. Results: Compared to the SL wear, RGP-CL wear changed the main axis astigmatism [Formula: see text] from -0.09 ± 0.34 to 0.34 ± 0.22 for the minimum astigmatism group, while the contrast VA was improved about 0.05 LogMAR (F = 8.06, p < 0.01). For the group with moderate astigmatism, significant reduction in [Formula: see text] was found for both fSL wear (t = 4.78, p < 0.001) and RGP-CL wear (t = 6.29, p < 0.0001). The changes in astigmatism were significantly correlated between the fSL and RGP-CL wears (r = 0.897, p < 0.0001 for [Formula: see text]; and r = 0.643, p = 0.004 for [Formula: see text]. Contrast VA was significantly improved for both fSL and RGP-CL wears and the improvements were significantly correlated between each other for all four contrast levels and two backgrounds. Conclusion: RGP-CL wear induces astigmatism for the eyes with minor astigmatism probably due to a correction of corneal astigmatism and thus a manifesting of the lens astigmatism. For the astigmatic eyes, RGP-CL wear has similar effect on correcting astigmatism as the spectacle lens wear with spherical-cylinder correction and also produces similar visual improvement.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering,Atomic and Molecular Physics, and Optics,Medicine (miscellaneous),Electronic, Optical and Magnetic Materials

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3