A Two-Step Horizon Optimum Switching Vector-Model Predictive Control with a Novel Shunt Active Filter Reference Current Extraction

Author:

Cheepati Kumar Reddy1ORCID,Rivera Marco2,Wheeler Patrick3,Subburaj Vivekanandan4,Krishnan Suresh5,Daram Suresh Babu5,Amaresh Karnam1

Affiliation:

1. Electrical and Electronics Engineering, Kandula Sreenivasa Reddy Memorial College of Engineering, Kadapa, Andhra Pradesh 516003, India

2. Department of Electrical Engineering, Universidad de Talca, Merced 437, Curicó 3460000, Chile

3. Power Electronics, Machines and Control Research Group, University of Nottingham, Nottingham, NG10 1NX, United Kingdom

4. School of Electrical and Electronics Engineering, Reva University, Bangalore, Karnataka 560024, India

5. Electrical and Electronics Engineering, Sree Vidyanikethan Engineering College, Tirupathi, Andhra Pradesh 517102, India

Abstract

Shunt active filters (SAFs) can be used for harmonic mitigation, reactive power compensation and power factor control in electrical distribution networks. Model predictive controller (MPC) can be used to give optimum performance for SAF’s due to its inherent cost function optimization. The SAF’s reference current extraction technique in finite control set-MPC (FCS-MPC) plays a vital role in the effectiveness of the SAF’s operation. The advantage of FCS-MPC is that it closely tracks the reference and injects the required compensating currents by optimizing the SAF’s switching vector and it does not require an external modulator for pulse generation. FCS-MPC can be implemented as either an optimal switching vector MPC (OSV-MPC) or an optimal switching sequence MPC (OSS-MPC) technique. The OSV-MPC technique is simple and efficient for SAF applications. In this paper, a novel reference current extraction technique, the inverse matrix average pq-synchronous reference frame (SRF) (IMApq-SRF) technique, is proposed along with the OSV-MPC technique. Practically a two-step delay compensation is essential in the implementation of the technique for the control of an SAF. Hence in this paper a two-step horizon OSV-MPC technique is proposed along with an IMApq-SRF reference current extraction technique to improve the power quality in distribution networks. The presented results show that the proposed methodology gives optimum SAF performance under a large range of supply and load conditions.

Publisher

World Scientific Pub Co Pte Ltd

Subject

Electrical and Electronic Engineering,Hardware and Architecture,Electrical and Electronic Engineering,Hardware and Architecture

Reference18 articles.

1. R. C. Dugan, M. F. Mc Granaghan, S. Santoso and H. W. Beaty , Electrical Power Systems Quality, 2nd edn. (McGraw Hill, New York, 2002), pp. 168–172.

2. Overview of Double Tuned Harmonic Filters in Improving Power Quality under Non Linear Load Conditions

3. A Novel Reference Current Extraction Technique with Multi-Functional Capability for Shunt Active Filter

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3