COMPARISON OF OPTICAL POLARIMETRY AND DIFFUSION TENSOR MR IMAGING FOR ASSESSING MYOCARDIAL ANISOTROPY

Author:

WALLENBURG MARIKA A.1,POP MIHAELA2,WOOD MICHAEL F. G.1,GHOSH NIRMALYA3,WRIGHT GRAHAM A.2,VITKIN I. ALEX4

Affiliation:

1. Ontario Cancer Institute, Division of Biophysics and Bioimaging, University Health Network and University of Toronto, Department of Medical Biophysics, 610 University Avenue, Toronto, Ontario, Canada M5G 2M9, Canada

2. Department of Medical Biophysics, University of Toronto, Sunnybrook Health Sciences Center, 2075 Bayview Avenue, Toronto, ON, Canada, M5N 3M5, Canada

3. IISER Kolkata, Mohanpur Campus, P. O. BCKV Campus Main Office, Mohanpur 741252, West Bengal, India

4. Ontario Cancer Institute, Division of Biophysics and Bioimaging, University Health Network and University of Toronto, Departments of Medical Biophysics and Radiation Oncology, 610 University Avenue, Toronto, Ontario, Canada M5G 2M9, Canada

Abstract

We have recently proposed an optical method for assessing heart structure that uses polarized light measurement of birefringence as an indicator of tissue anisotropy. The highly aligned nature of healthy cardiac muscle tissue has a detectable effect on the polarization of light, resulting in a measurable phase shift ("retardance"). When this organized tissue structure is perturbed, for example after cardiac infarction (heart attack), scar tissue containing disorganized collagen is formed, causing a decrease in the measured retardance values. However, these are dependent not only on tissue anisotropy, but also on the angle between the tissue's optical anisotropy direction and the beam interrogating the sample. To remove this experimental ambiguity, we present a method that interrogates the sample at two different incident beam angles, thus yielding enough information to uniquely determine the true magnitude and orientation of the tissue optical anisotropy. We use an infarcted porcine heart model to compare these polarimetry-derived anisotropy metrics with those obtained with diffusion tensor magnetic resonance imaging (DT-MRI). The latter yields the anisotropy and the direction of tissue water diffusivity, providing an independent measure of tissue anisotropy. The optical and MR results are thus directly compared in a common ex vivo biological model of interest, yielding reasonable agreement but also highlighting some technique-specific differences.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering,Atomic and Molecular Physics, and Optics,Medicine (miscellaneous),Electronic, Optical and Magnetic Materials

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3