Real-Time Closed-Loop Functional Electrical Stimulation Control of Muscle Activation with Evoked Electromyography Feedback for Spinal Cord Injured Patients

Author:

Li Zhan12,Guiraud David2,Andreu David2,Gelis Anthony3,Fattal Charles34,Hayashibe Mitsuhiro25

Affiliation:

1. School of Automation Engineering, University of Electronic Science and Technology of China, Chengdu, P. R. China

2. INRIA, University of Montpellier, Montpellier, France

3. Centre Neurologique PROPARA, Montpellier, France

4. COS DIVIO, Dijon, France

5. Tohoku University, Sendai, Japan

Abstract

Functional electrical stimulation (FES) is a neuroprosthetic technique to help restore motor function of spinal cord-injured (SCI) patients. Through delivery of electrical pulses to muscles of motor-impaired subjects, FES is able to artificially induce their muscle contractions. Evoked electromyography (eEMG) is used to record such FES-induced electrical muscle activity and presents a form of [Formula: see text]-wave. In order to monitor electrical muscle activity under stimulation and ensure safe stimulation configurations, closed-loop FES control with eEMG feedback is needed to be developed for SCI patients who lose their voluntary muscle contraction ability. This work proposes a closed-loop FES system for real-time control of muscle activation on the triceps surae and tibialis muscle groups through online modulating pulse width (PW) of electrical stimulus. Subject-specific time-variant muscle responses under FES are explicitly reflected by muscle excitation model, which is described by Hammerstein system with its input and output being, respectively, PW and eEMG. Model predictive control is adopted to compute the PW based on muscle excitation model which can online update its parameters. Four muscle activation patterns are provided as desired control references to validate the proposed closed-loop FES control paradigm. Real-time experimental results on three able-bodied subjects and five SCI patients in clinical environment show promising performances of tracking the aforementioned reference muscle activation patterns based on the proposed closed-loop FES control scheme.

Publisher

World Scientific Pub Co Pte Lt

Subject

Computer Networks and Communications,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3