Computer-Assisted Three-Dimensional Corrective Osteotomy for Malunited Fractures of the Distal Radius Using Prefabricated Bone Graft Substitute

Author:

Shintani Kosuke1,Kazuki Kenichi2,Yoneda Masahiro3,Uemura Takuya1,Okada Mitsuhiro1,Takamatsu Kiyohito4,Nakamura Hiroaki1

Affiliation:

1. Department of Orthopedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan

2. Gakuen-Minami Clinic, Nara, Japan

3. Yoneda Clinic, Osaka, Japan

4. Department of Orthopedic Surgery, Yodogawa Christian Hospital, Osaka, Japan

Abstract

Background: Three-dimensional computed tomography (3D-CT) imaging has enabled more accurate preoperative planning. The purpose of this study was to investigate the results of a novel, computer-assisted, 3D corrective osteotomy using prefabricated bone graft substitute to treat malunited fractures of the distal radius. Methods: We investigated 19 patients who underwent the computer-assisted 3D corrective osteotomy for a malunited fracture of the distal radius after the operation was stimulated with CT data. A prefabricated bone graft substitute corresponding to the patient’s bone defect was implanted and internal fixation was performed using a plate and screws. We compared postoperative radiographic parameters of the patient’s operated side with their sound side and analyzed clinical outcomes using Mayo wrist score. Results: All patients achieved bone union on X-ray imaging at final follow-up. The mean differences of palmar tilt, radial inclination and ulnar variance between the operation side and the sound side were 4.3°, 2.3° and 1.2 mm, respectively. The Mayo wrist score was fair in 4 patients and poor in 15 patients before surgery. At the final follow-up after surgery, the scores improved to excellent in 3 patients, good in 11 patients and fair in 5 patients. There were two patients with correction loss at the final follow-up, but no patient complained of hand joint pain. Conclusions: We believe that computer-assisted 3D corrective osteotomy using prefabricated bone graft substitute achieved good results because it worked as a guide to the accurate angle.

Publisher

World Scientific Pub Co Pte Lt

Subject

General Medicine

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. 3D-assisted corrective osteotomies of the distal radius: a comparison of pre-contoured conventional implants versus patient-specific implants;European Journal of Trauma and Emergency Surgery;2024-01-23

2. A comparison of 3-D CT and 2-D plain radiograph measurements of the wrist in extra-articular malunited fractures of the distal radius;Journal of Hand Surgery (European Volume);2023-11-21

3. Functional outcome of 2-D- and 3-D-guided corrective forearm osteotomies: a systematic review;Journal of Hand Surgery (European Volume);2023-09-25

4. Personalized Surgical Instruments;Additive Manufacturing in Biomedical Applications;2022-09-12

5. Management of Distal Radius Malunions;Wrist and Elbow Arthroscopy with Selected Open Procedures;2021-11-17