CT Based Characterization of Volar Surface of Distal Radius: Can an Ideal Volar Plate for Fixation of Distal Radial Fractures be Designed?

Author:

Kumar Arvind1,Passey Jigyasa2,Chouhan Dushyant3,Saini Manish4,Narang Amit3

Affiliation:

1. Department of Orthopaedics, Hamdard Institute of Medical Sciences and Research, New Delhi, India

2. Department of Anatomy, Maulana Azad Medical College, New Delhi, India

3. Department of Orthopaedics, Lady Hardinge Medical College, New Delhi, India

4. Department of Orthopaedics, Shalby Hospital, Surat, Gujarat, India

Abstract

Background: Literature has limited evidence concerning the morphology of volar surface of distal radius. A mismatch between the plate-contour and contour of the actual volar bony surface can result in malreduction. The purpose of this study is to analyze the normal curvature morphology of volar surface of distal radius and related parameters that can help in designing of the volar plates for fixation of distal radial fractures. Methods: We retrospectively analyzed CT scans of uninjured healthy distal radii performed during a one year period (2018–2019). The mediolateral extent of the pronator quadratus line, the mediolateral curve of the pronator quadratus line, the mediolateral surface angle between intermediate column and radial column of distal radius, the curvatures and locations of their vertices for radial and intermediate columns were measured. Results: A total of 84 CT-based studies were analyzed. The mediolateral extent of the pronator quadratus line, the mediolateral curve of the pronator quadratus line, and the mediolateral surface angle between intermediate column and radial column of the distal radius were 24.27 mm, 144.8 degrees and 163.1 degrees, respectively. The mean volar curvatures of the radial and intermediate columns were 156.5 and 151.4 degrees, respectively and distances of their vertices from the pronator-quadratus line were 10.96 mm and 14.13 mm, respectively. Conclusions: Considerable variations occur in curvature morphology of distal radial volar surface. A best fit rather than an anatomical fit can be considered during implant selection owing to these variations. Besides volar curvature of radial and ulnar columns, location of their vertices, mediolateral angulation and surface curvature between these columns at the level of watershed line should also be considered in plate selection. A combination of a few serial increments of the described parameters in the designs of volar fixation plates would be helpful for surgeons in the best implant selection.

Publisher

World Scientific Pub Co Pte Lt

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3