Anthropometric Study of Proximal Radius in Below-Average Height Thai Women and Its Correlation with Commercially Available Radial Head Prostheses

Author:

LUENAM Suriya1,TANTHAPRABHA Natpawee1,KOSIYATRAKUL Arkaphat1

Affiliation:

1. Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand

Abstract

Background: Most radial head prostheses were designed in Western countries based on the anatomical characteristics of Western populations. We hypothesised that these prostheses are too large for below-average height Thai women. The objective of this study is to evaluate the anthropometric parameters of the proximal radius in such a population and its correlation with commercially available prostheses. Methods: Dominant elbows of 124 Thai women whose height was <155 cm were studied. Using the standard anteroposterior and lateral radiographic images, the head diameter and thickness, the distance between the articular surface and radial tuberosity, the narrowest intra-medullary canal diameter and the narrowest outer diameter of the radial neck were measured. Correlations between body height and each radiographic parameter were assessed using the Pearson correlation coefficient (PCC). The specifications of the commercial metallic radial head implants were reviewed and used to evaluate the relevant radiographic parameters. Results: Mean of the minimum and maximum head diameter was 18.54 ± 1.11 mm and 19.13 ± 1.17 mm, respectively; the thickness was 7.43 ± 0.69 mm, the distance between the articular surface and tuberosity was 19.05 ± 1.45 mm, the intra-medullary canal diameter was 7.63 ± 1.2 mm and the outer diameter of the radial neck was 11.13 ± 1.26 mm. There is a poor correlation between the participant’s height and each parameter (PCC ≤ 0.50). In 24.2% of the participants, the smallest size of prosthetic designs with a head diameter of 20 mm is larger than +2 mm in reference to minor diameter. The minimum prosthetic head thickness is greater than the average value of the participants in 12 out of 15 designs. One participant has an outer neck diameter smaller than the smallest stem diameter of three designs. Conclusions: Surgeons must be aware that commercially available radial head replacement implants may be too large for below-average height Thai women. Level of Evidence: Level IV (Prognostic)

Publisher

World Scientific Pub Co Pte Ltd

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3