Comparison of Calculated Skin Doses in Cineradiography and Four Dimensional Kinematic Computed Tomography of the Wrist

Author:

Goelz Leonie12,Asmus Ariane3,Kim Simon4,Diehl Josha5,Eisenschenk Andreas34,Mutze Sven12

Affiliation:

1. Department of Radiology and Neuroradiology, BG Klinikum Unfallkrankenhaus Berlin, Berlin, Germany

2. Institute for Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany

3. Department of Hand-, Replantation- and Microsurgery, BG Klinikum Unfallkrankenhaus Berlin, Berlin, Germany

4. Department of Hand Surgery and Microsurgery, University Medicine Greifswald, Greifswald, Germany

5. Institute for Mathematics and Computer Science, University Medicine Greifswald, Greifswald, Germany

Abstract

Background: Previous studies have discussed the diagnostic value of four dimensional kinematic CT in cases of carpal instabilities. This analysis compares calculated skin doses of 4D CT and conventional cineradiography of the wrist in cases of suspected SLL rupture. Methods: Retrospective calculation and interpolation of skin doses and effective doses for ten consecutive 4D CT examinations and 41 cineradiographies for suspected lesions of the scapholunate ligament. Standardised anterior-posterior and lateral cine sequences using a flat-panel digital subtraction imager and of 4D kinematic CT using a dual-source scanner were acquired and acquisition parameters recorded. We tested if the skin dose of 4D CT is different from cineradiography. Results: Median dose area product (DAP) of cineradiography was 135.34 cGycm2 resulting in a calculated median skin dose of 32.6 mSv (confidence interval 26.86–42.90 mSv) and an estimated effective skin dose of 3.26 µSv. CT dose index (CTDI) for 4D examinations was recorded to be 26.79 mGy and the dose-length product (DLP) was 150 mGy × cm. This resulted in an estimated skin dose of 34 mSv, which is covered by the confidence interval of cineradiography, and an effective skin dose of 3.4 µSv. Conclusions: Skin dose calculations are comparable for 2D cineradiography in two plains and 4D kinematic CT of the wrist. Calculated effective doses are < 0.01 mSv.

Publisher

World Scientific Pub Co Pte Ltd

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3