Biomechanics Study of the Holding Power between Tendon and Suture Using Different Techniques

Author:

Liawrungrueang Wongthawat1,Wongsiri Sunton1

Affiliation:

1. Department of Orthopedic, Faculty of Medicine, Prince of Songkla University, Songkhla, Thailand

Abstract

Background: The holding power of a repaired flexor tendon injury is related to surface sutures, suture material and different techniques. Nowadays, a barbed suture material offers the possibility of knotless flexor tendon repair but many hospitals use non-barbed suture materials. The purpose of this study was to compare a barbed suture material and a non-barbed suture material for primary stability under static loading and increased knots in the non-barbed suture material (knot technique) for increased holding power of tendons in animal testing. Methods: Forty-five fresh porcine tendons were randomized into three groups: Group 1 (grasping technique group) used a four-strand core suture grasping a four-strand modified Kessler suture by non-barbed suture material [Non-absorbable monofilament polybutester 3–0] was used to repair the tendon with a surgical knot; in Group 2 (knot technique group) a four-strand core suture used the knot technique by non-barbed suture material [Non-absorbable monofilament polybutester 3–0] to repair the tendon with a continuous suture adding surgical knots in the same place as the surgical knot at the repair sites; and Group 3 (knotless technique group) used a four-strand core suture with the knotless technique in modified Kessler suture with barbed suture material [Non-absorbable monofilament polybutester 3–0] to repair the tendon without a knot. Our objective was to compare the ultimate tensile strength between the groups. Results: The mean tensile strength was 30.38 ± 5.04 N for group 1, 41.71 ± 2.62 for group 2 and 47.53 ± 4.89 for the group 3. The ANOVA test revealed a significant difference among the various techniques (p < 0.05). The highest tensile strength was found in the knotless technique using barbed suture material group. Conclusions: The knotless technique using barbed suture material demonstrated the highest tensile strength in suture repairs. The maximum tensile strength was significantly higher in this group.

Publisher

World Scientific Pub Co Pte Lt

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3