Biomechanical Evaluation Comparing Pulvertaft Weave and Side-to-Side Tenorrhaphy Using Porcine Tendons

Author:

Sajid Soha1,Day Emily1,Kuiper Jan Herman1,Singh Rohit1,Pickard Simon1

Affiliation:

1. Department of Upper Limb Surgery, Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, UK

Abstract

Background: Pulvertaft Weave (PTW) is an established method of tenorrhapy in tendon transfers. Previous studies have suggested that a Side-to-Side (STS) tenorrhapy is easier to perform has the same advantages and has greater load to failure, ultimate load and stiffness compared to PTW. However, there is insufficient data comparing behaviour of STS and PTW during cyclical loading. The aim of this study is to compare these two methods in terms of creep after cyclic landing. Methods: Fresh porcine flexor digitorum tendons were used. Ten tendon PTW and ten STS repairs were performed. Cross sectional diameter was measured. The tendon repairs were tested by applying tension up to 25N for 100 cycles, followed by tension up to 75N for 100 cycles, followed by loading to failure. Force-displacement data was used to determine the creep of the repaired tendon. Results: All tendons survived 100 cycles of loading at 25N. After 1 cycle of loading, the mean cyclic creep in the PTW group was almost 3 mm larger than in the STS group (p = 0.046). After 100 cycles, the mean cyclic creep in the PTW group was 4.4 mm larger (p = 0.008). The cyclic creep rate was significantly larger in the PTW group (p < 0.001). All STS but only four PTW repairs survived after cyclic loading at 75N (p = 0.01). After 1 cycle and 100 cycles, mean creep of the surviving PTW samples was almost 7 mm (p = 0.006) and almost 9 mm (p = 0.004) larger than the STS group. The mean load to failure was four times larger in the STS group than the PTW group (p = 0.004). Conclusions: STS repairs have a significantly smaller permanent elongation after cyclic loading at 25N and 75N, a significantly smaller cyclic creep rate, require a significantly larger load to fail. This implies that STS repairs are less likely to elongate after cyclic loading and can withstand greater loads. These properties can be valuable in allowing patients to commence mobilisation immediately after surgery.

Publisher

World Scientific Pub Co Pte Lt

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3