Knotless Tendon Repair with a Resorbable Barbed Suture: An In-vivo Comparison in the Turkey Foot

Author:

PELTZ Tim S.123,MCMAHON James E.1,SCOUGALL Peter J.3,GIANOUTSOS Mark P.12,OLIVER Rema1,WALSH William R.1

Affiliation:

1. Surgical and Orthopaedic Research Laboratories, Prince of Wales Clinical School, University of New South Wales, Randwick, Sydney, NSW, Australia

2. Plastic, Reconstructive and Hand Surgery Department, Prince of Wales Hospital, Randwick, Sydney, NSW, Australia

3. Hand surgery Department St Luke’s Hospital and Sydney Hospital, Potts Point, Sydney, NSW, Australia

Abstract

Background: Un-knotted barbed suture constructs are postulated to decrease repair bulk and improve tension loading along the entire repair site resulting in beneficial biomechanical repair properties. Applying this repair technique to tendons has shown good results in ex-vivo experiments previously but thus far no in-vivo study could confirm these. Therefore, this current study was conducted to assess the value of un-knotted barbed suture repairs in the primary repair of flexor tendons in an in-vivo setting. Methods: Two groups of 10 turkeys (Meleagris gallapovos) were used. All turkeys underwent surgical zone II flexor tendon laceration repairs. In group one, tendons were repaired using a traditional four-strand cross-locked cruciate (Adelaide) repair, while in group two, a four-strand knotless barbed suture 3D repair was used. Postoperatively repaired digits were casted in functional position, and animals were left free to mobilise and full weight bear, resembling a high-tension post-op rehabilitation protocol. Surgeries and rehabilitations went uneventful and no major complications were noted. The turkeys were monitored for 6 weeks before the repairs were re-examined and assessed against several outcomes, such as failure rate, repair bulk, range of motion, adhesion formation and biomechanical stability. Results: In this high-tension in-vivo tendon repair experiment, traditionally repaired tendons performed significantly better when comparing absolute failure rates and repair stability after 6 weeks. Nevertheless, the knotless barbed suture repairs that remained intact demonstrated benefits in all other outcome measures, including repair bulk, range of motion, adhesion formation and operating time. Conclusions: Previously demonstrated ex-vivo benefits of flexor tendon repairs with resorbable barbed sutures may not be applicable in an in-vivo setting due to significant difference in repair stability and failure rates. Level of Evidence: Level IV (Therapeutic)

Publisher

World Scientific Pub Co Pte Ltd

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3