The critical pressure is determined for a trapezoidal vault with rigid members and semi-rigid joints. For maximal volume enclosed per boundary length, it is found that the critical pressure is highest when the vault symmetrical, with top three pieces 39.64% of the base length. The upper two joints should also be heavily strengthened.