INTERACTION EFFECT BETWEEN BEAM DIAMETER AND ENERGY DENSITY IN LASER-INDUCED TACTILE PERCEPTION

Author:

CHOI MI-HYUN1,KIM HYUNG-SIK1,JO JI-HUN1,KIM JI-SUN1,JUN JAE-HOON1,PARK JONG-RAK2,CHUNG SOON-CHEOL1

Affiliation:

1. Biomedical Engineering, BK21+ Research Institute of Biomedical Engineering, Research Institute of Biomedical Engineering, School of ICT Convergence Engineering, College of Science & Technology, Konkuk University, Chungju, South Korea

2. Department of Photonic Engineering, Chosun University, Gwangju, South Korea

Abstract

This study aims to investigate the interaction effect between the beam diameter and energy density, which are perceived as laser-induced tactile perception by humans, by diversely varying the laser parameters, beam diameter, and energy. Eight healthy male college students of 23.5[Formula: see text][Formula: see text][Formula: see text]1.7 years participated in the study. The range of the beam diameter of the displayed laser stimulation was between 0.03[Formula: see text]mm and 8[Formula: see text]mm, and a total of 21 sizes were displayed. The laser energy was sequentially displayed from the minimum energy that can be displayed by one beam diameter to the maximum energy range that does not exceed the maximum permissible exposure (MPE) level since the energy varies according to the beam diameter. The laser energy was controlled by an optical density ([Formula: see text]) filter and was measured by an optical power meter (energy meter). Furthermore, the beam diameter was adjusted by moving the lens, which was confirmed with the beam profiler. The experimental test consists of the control phase (19[Formula: see text]s), stimulus phase (7[Formula: see text]s), and response phase (4[Formula: see text]s); the total duration of the test was 30[Formula: see text]s. The stimulus phase is the period in which stimulation was displayed on the skin through laser irradiation, and the stimulation was displayed by changing the beam diameter and the energy from the laser. The total number of beam diameter and energy pairs displayed to the subjects was 113 and 5 trials of irradiation were conducted for each pair. Stimulation perception response was recorded by pressing the response buttons during the response phase, and the responses were predefined as “no feeling,” “tactile sensation”, and “pain.” Through the extracted response data from the response phase, the beam diameter and energy density pair in which more than 50% of the subjects responded as having perceived tactile sensation were selected from the possible laser energy that could be displayed from one beam diameter. The simulation results showed that increasing the beam diameter increased the penetration depth, indicating an effective energy transfer to the skin. Therefore, increasing the beam diameter results in increased scattering, and hence increased penetration depth, and ultimately a more effective energy transfer. Therefore, increased beam diameter results in higher energy transfer efficiency, indicating that the required energy density by more than 50% of the subjects to perceive tactile sensation decreased.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3