DIFFERENCES BETWEEN CONTRALATERAL BONES OF THE HUMAN LOWER LIMBS: A MULTISCALE INVESTIGATION

Author:

CRISTOFOLINI LUCA12,BALEANI MASSIMILIANO1,SCHILEO ENRICO1,VAN SINT JAN SERGE3,JUSZCZYK MATEUSZ MARIA12,ÖHMAN CAROLINE12,ZWIERZAK IWONA1,LEFÈVRE PHILIPPE3,JUSZCZYK JAN MARIA4,VICECONTI MARCO5

Affiliation:

1. Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy

2. Department of Industrial Engineering, School of Engineering and Architecture, University of Bologna, Italy

3. Laboratory of Anatomy, Biomechanics and Organogenesis, Université Libre de Bruxelles, Belgium

4. Institute of Electronics and Computer Science, Faculty of Automatic Control, Silesian University of Technology, Gliwice, Poland

5. Department of Mechanical Engineering, University of Sheffield, Sheffield, UK

Abstract

This study addressed side asymmetry between human lower limb long bones. A multiscale approach was taken to investigate differences between contralateral femurs, tibias and fibulas, at body-level (total-body CT-scans, anatomical dissection), organ-level (volume and moments of areas; structural stiffness and strain distribution in bending and torsions) and tissue-level (mineral density, elastic modulus, hardness). Because of the large amount of measurements taken, the study was limited to two donors. However, high statistical power within the same donor was achieved thanks to a large number of highly-repeatable measurements. Muscle cross-sections suggested that both donors were right-legged. The right bones had higher structural stiffness (up to +115%, statistically significant, except for the tibia). The right bones also experienced generally lower strain than the contralateral ones (up to -25%, statistically significant). The right bones had larger volume (up to +16%) and moments of area (up to +116%, statistically significant in most cases) than the left ones. Difference in tissue density between contralateral bones (< 7%) was not statistically significant in most cases. Also the differences found in elastic modulus of the femur cortical tissue (2–5%) were not statistically significant. Similarly, tissue hardness in the right bones was only marginally higher than in the contralateral ones (+1% to +4%, not statistically significant). Therefore, it seems that structural differences between contralateral bones associated with laterality are mainly explained by differences in bone quantity (volume) and organization (area moments). Bone tissue quality (density, hardness) seems to give a marginal contribution to structural side asymmetry.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3