COMBINED USE OF PARALLEL-PLATE COMPRESSION AND FINITE ELEMENT MODELING TO ANALYZE THE MECHANICAL PROPERTIES OF INTACT PORCINE LENS

Author:

WANG KEHAO1,VENETSANOS DEMETRIOS T.2,WANG JIAN3,PIERSCIONEK BARBARA K.1

Affiliation:

1. School of Science and Technology, Nottingham Trent University, Clifton Campus, Clifton Lane, Nottingham, NG11 8NS, UK

2. School of Mechanical, Aerospace and Automotive Engineering, Coventry University, Priory Street, Coventry, CV1 5FB, UK

3. Faculty of Science Engineering and Computing, Kingston University, Penrhyn Road, Kingston-Upon-Thames, KT1 2EE, UK

Abstract

The objective of this study is to explore the feasibility of a compression test for measuring mechanical properties of intact eye lenses using novel parallel plate compression equipment to compare the accuracy of implementing a classical Hertzian model and a newly proposed adjusted Hertzian model to calculate Young’s modulus from compression test results using finite element (FE) analysis. Parallel-plate compression tests were performed on porcine lenses. An axisymmetric FE model was developed to simulate the experimental process to evaluate the accuracy of using the classical Hertzian theory of contact mechanics as well as a newly proposed adjusted Hertzian theory model for calculating the equivalent Young’s modulus. By fitting the force-displacement relation obtained from FE simulations to both the classical and adjusted Hertzian theory model and comparing the calculated modulus to the input modulus of the FE model, the results demonstrated that the classical Hertzian theory model overestimated the Young’s modulus with a proportional error of over 10%. The adjusted Hertzian theory model produced results that are closer to original input values with error ratios all lower than 1.29%. Measurements of three porcine lenses from the parallel plate compression experiments were analyzed with resulting values of Young’s modulus of between 3.2[Formula: see text]kPa and 4.3[Formula: see text]kPa calculated. This study demonstrates that the adjusted Hertzian theory of contact mechanics can be applied in conjunction with the parallel-plate compression system to investigate the overall mechanical behavior of intact lenses.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370