BIOKINETIC AND DOSIMETRIC ASSESSMENT OF FLUORINE 18 IN HEALTHY VOLUNTEERS SUBJECTED TO 18F–NaF PET/CT BONE SCANS VIA COMPARTMENTAL/MATLAB MODELS AND IN-VIVO STUDY

Author:

KAO PAN-FU12,KUO HSUN-NAN34,LIU SHIH-JYUN35,YEH DA-MING67,PAN LUNG-KWANG3

Affiliation:

1. Department of Nuclear Medicine, Chung Shan Medical University Hospital, Taichung 402, Taiwan, ROC

2. School of Medicine, Chung Shan Medical University, Taichung 402, Taiwan, ROC

3. Graduate Institute of Radiological Science, Central Taiwan University of Science and Technology, Takun, Taichung 406, Taiwan, ROC

4. Division of Cardiology, Yuan Rung Hospital, Yuanlin, Changhua 510, Taiwan, ROC

5. Department of Radiation Oncology, E-Da Cancer Hospital, Kaohsiung 824, Taiwan, ROC

6. School of Medical Imaging and Radiological Sciences, Chung Shan Medical University, Taichung 402, Taiwan, ROC

7. Department of Diagnostic Radiology, Chung Shan Medical University Hospital, Taichung 402, Taiwan, ROC

Abstract

Objective: This study quantified the time-dependent concentration of [Formula: see text]F–NaF in critical organs according to a simplified compartmental biokinetic model with clinical verification. Methods: The eleven volunteers were given [Formula: see text][Formula: see text]MBq [Formula: see text]F–NaF administration, then scanned (with 15[Formula: see text]min-collection, every 20[Formula: see text]min, for 200 consecutive min) with a Philips Gemini GXL PET/CT. The empirical data were collected and normalized as the input dataset for MATLAB program. A six-compartmental model was created as a set of time-dependent differential equations and analyzed by the MATLAB to optimize the correlation between the in vivo data and calculated results. The six compartments were: body fluid, bone, kidney, liver, remainder and excretion, while kidney and liver compartments were conventionally split into two subunits with different half-lives to fit properly the empirical data. Results: The average biological half-lives of body fluid, bone, kidney-1, kidney-2, liver-1, liver-2 and the remainder (rest of body) were assessed as [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text][Formula: see text]min, respectively. A dimensionless AT index of disagreement between the empirical data and MATLAB optimal solutions was proposed of validating the applied acquisition system and analytical method feasibility. The body fluid and bone AT values did not exceed 20%. The proposed refined equation yielded the internal dose from both gamma- and beta-rays ([Formula: see text] cSv as [Formula: see text] cSv/MBq), which exhibited good correlation with literature (0.00168–0.00270 cSv/MBq). Conclusion: The proposed MATLAB-based fitting of in-vivo data with the theoretical results was instrumental for assessing the radiation dose received by the PET/CT bone scan participants.