INVESTIGATION OF THE LOADING AT THE KNEE JOINT COMPLEX USING AN EMG-BASED CONSTITUTIVE LAW FOR SKELETAL MUSCLE FORCE

Author:

KNODEL NATHAN B.1,CALVERT L. BRIE1,BYWATER EMILY A.1,LAMIA JOSEPH P.2,PATEL SHIV N.3,NAUMAN ERIC A.1234ORCID

Affiliation:

1. Department of Mechanical Engineering, 585 Purdue Mall, West Lafayette, IN 47906, United States

2. Department of Biomedical Engineering, 585 Purdue Mall, West Lafayette, IN 47906, United States

3. Department of Basic Medical Sciences, 585 Purdue Mall, West Lafayette, IN 47906, United States

4. Department of Biomedical Engineering, 2901 Woodside Drive, Cincinnati, OH 45219, United States

Abstract

This study investigated the predictive ability of the skeletal muscle force model presented by Knodel et al. [Knodel NB, Lawson LB, Nauman EA, “An emg-based constitutive law for force generation in skeletal muscle-part i: Model development,” J Biomech Eng (in press), doi: 10.1115/1.4053568] on the knee joint. It has previously been validated on the ankle joint [Knodel NB, Calvert LB, Bywater EA, Lamia JP, Patel SN, Nauman EA, “An emg-based constitutive law for force generation in skeletal muscle-part ii: Model validation on the ankle joint complex,” Submitted for Publication] and this paper aimed to identify how well it, and the solution process, performed on a more complex articulation. The knee joint’s surrounding musculoskeletal tissue loading was also identified. Ten subjects (five male and five female) performed six exercises targeting the muscles that cross the knee joint. Motion capture, electromyography, and force plate data was collected during the exercises for use in the analysis program written in MATLAB and magnetic resonance images were used to observe subject-specific ligament and tendon data at the knee articulation. OpenSim [Delp, SL, Anderson FC, Arnold AS, Loan P, Habib A, John CT, Guendelman E, Thelen DG, “Opensim: Open-source software to create and analyze dynamic simulations of movement,” IEEE Trans Biomed Eng 54(11):1940–1950, 2007, doi: 10.1109/TBME.2007.901024] was used for scaling a generic lower extremity anatomical model of each subject. Five of the six exercises were used to calculate each muscle’s constant, [Formula: see text] [Knodel NB, Lawson LB, Nauman EA, “An emg-based constitutive law for force generation in skeletal muscle-part i: Model development,” J Biomech Eng (in press), doi: 10.1115/1.4053568; Knodel NB, Calvert LB, Bywater EA, Lamia JP, Patel SN, Nauman EA, “An emg-based constitutive law for force generation in skeletal muscle-part ii: Model validation on the ankle joint complex,” Submitted for Publication], and the sixth was used as a testing set to identify the model’s predictive ability. Average percent errors ranged from 9.4% to 26.5% and the average across all subjects was 20.6%. The solution process produced physiologically relevant muscle forces and the surrounding tissue loading behaved as expected between the various exercises without approaching respective tensile strength values.

Publisher

World Scientific Pub Co Pte Ltd

Subject

Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3