MOTION CAPTURE ANALYSIS OF EX VIVO KNEE KINEMATIC SIMULATOR: A COMPREHENSIVE EXPERIMENTAL PROTOCOL

Author:

BORI EDOARDO1ORCID,INNOCENTI BERNARDO1

Affiliation:

1. BEAMS Department, Université Libre de Bruxelles, Av. Franklin Roosevelt 50, Bruxelles, 1050, Belgium

Abstract

Preface: Understanding knee kinematics is a fundamental prerequisite to address restoration in pathological joints; these performances represent the goal to achieve after the treatment. Experimental activities addressing knee kinematics often involve Motion Capture systems to acquire information, both for in vivo and ex vivo studies. This technique allows a complete analysis of the joint kinematics and is able to provide useful results for the comparison mentioned above. Objectives: The definition of a reproducible and straightforward protocol represents a beneficial factor to improve both reliability and the time required: in this study a new protocol for kinematics experimental activities on ex vivo knee specimens was developed, validated and tested. Methods: Synthetic bones were chosen for the analysis and different Total Knee Arthroplasties models were selected (a Cruciate Retaining, a Posterior Stabilized, a Constrained Condylar Knee and a Rotating Hinge). A dedicated frame was used to support and secure the knee specimens and pair the extensor mechanism to a motor. The Motion Capture System was assembled and paired with dedicated marker-sets to be fixed to the specimens. A post-processing tool was developed to analyze the outputs and was validated with a goniometer. A series of force-driven tasks were defined, implemented and run in the motor system for all the different prosthesis configurations and kinematics output were analyzed, comparing the outputs with the expected results. Results: The validation of the system returned satisfying results in terms of correspondence between the angles imposed and the ones measured, with an average error below [Formula: see text] and a standard deviation below [Formula: see text] for each kind of rotation. The results from the different testing were coherent with the type of specimens and prostheses tested. Conclusions: This study proved that the protocol and testing set-up developed for knee kinematics in vitro analysis are able to provide reliable and coherent data, as proven by the post-processing validation and by the testing campaign on synthetic specimens.

Publisher

World Scientific Pub Co Pte Ltd

Subject

Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3