TAGUCHI METHOD-BASED OPTIMIZATION OF THE MINIMUM DETECTABLE DIFFERENCE OF A CARDIAC X-RAY IMAGING SYSTEM USING A PRECISE LINE PAIR GAUGE

Author:

PAN LUNG-FA12,WU KENG-YI123,CHEN KE-LIN14,KITTIPAYAK SAMRIT5,PAN LUNG-KWANG1

Affiliation:

1. Graduate Institute of Radiological Science, Central Taiwan University of Science and Technology, Takun, Taichung 406, Taiwan, ROC

2. Department of Cardiology, Taichung Armed Forces General Hospital, Taichung 411, Taiwan, ROC

3. Division of Cardiology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan, ROC

4. Department of Radiology, Ningbo First Hospital, Ningbo 315012, Zhejiang, P. R. China

5. Department of Radiological Technology, Faculty of Medical Technology, Mahidol University, Bangkok, Thailand

Abstract

Objective: To optimize the minimum detectable difference (MDD) of a cardiac X-ray imaging system using the Taguchi L8(27) analysis and a precise line pair (LP) gauge. Methods: The optimal combination of the four critical factors of the cardiac X-ray imaging system, namely X-ray focus, kilovoltage (kVp), milliamper-seconds (mAs) and source image distance (SID), providing the MDD was calculated via the Taguchi analysis and experimentally verified. Two (low and high) levels were assigned for each factor, and eight combinations of four factors were used to acquire instant X-ray images using an NDT commercial LP gauge (with a gauge length of 64[Formula: see text]mm and a width of [Formula: see text][Formula: see text]mm). The latter had five lines and was split gradually from top to bottom for the inspection of X-ray images, whose quality was ranked by three well-trained radiologists according to the double-blind criterion. The ranking grade was given by sharp contrast, low noise and precision to distinguish the LP. Accordingly, the MDD was derived to represent the spatial resolution of instant X-ray images by the revised Student’s [Formula: see text]-test analysis. The optimal combination of factors was experimentally identified and clinically verified in the follow-up inspections. Results: For the conventional setting, Group No. 7 (which obtained the highest grade among eight groups) and the optimal setting, the obtained MDD values were [Formula: see text], [Formula: see text] and [Formula: see text][Formula: see text]mm, respectively, while the LP (line pair/mm) interpolated from the gauge scale amounted to [Formula: see text], [Formula: see text] and [Formula: see text][Formula: see text]LP/mm, respectively. Conclusion: The Taguchi L8 analysis was proved to be instrumental in optimizing the cardiac X-ray imaging system MDD and is recommended to be used jointly with the revised Student’s [Formula: see text]-test analysis for improving the spatial resolution of instant X-ray images.

Funder

Ministry of Science and Technology of Taiwan

Taichung Armed Forces General Hospital in Taiwan

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering