OPTIMIZING THE MINIMUM DETECTABLE DIFFERENCE OF COMPUTED TOMOGRAPHY SCANNED IMAGES VIA THE TAGUCHI ANALYSIS: A FEASIBILITY STUDY WITH AN INDIGENOUS HEPATIC PHANTOM AND A LINE GROUP GAUGE

Author:

PENG BING-RU12,KITTIPAYAK SAMRIT3,PAN LUNG-FA14,PAN LUNG-KWANG1

Affiliation:

1. Graduate Institute of Radiological Science, Central Taiwan University of Science and Technology, Takun, Taichung 406, Taiwan, ROC

2. Department of Radiology Taichung, Armed Forces General Hospital, Taichung 411, Taiwan, ROC

3. Department of Radiological Technology, Faculty of Medical Technology, Mahidol University, Bangkok, Thailand

4. Department of Cardiology, Taichung Armed Forces, General Hospital, Taichung 411, Taiwan, ROC

Abstract

Objective: The minimum detectable difference (MDD) of computed tomography (CT) scanned images was quantified and optimized according to an indigenous hepatic phantom, line group gauge and Taguchi [Formula: see text] optimization analysis in this work. Methods: Optimal combinations of CT scan factors in every group with the level organization were judged using the Taguchi analysis, in which every factor was organized into only 18 groups, creating evaluated outcomes with the same confidence as if every factor was analyzed independently. The five practical factors of the CT scan were (1) kVp, (2) mAs, (3) pitch increment, (4) field of view (FOV) and (5) rotation time for one loop of CT scan. Insofar as each factor had two or three levels, the total number of 162 (i.e., [Formula: see text]) combinations was considered. Results: The optimal setting was 120[Formula: see text]kVp, 300[Formula: see text]mAs, 0.641 pitch, 320[Formula: see text]mm FOV and 1.0[Formula: see text]s of rotation time of CT scan. The minimal MDD was 2.65[Formula: see text]mm under 0.39[Formula: see text]mm of the slit depth from the revised Student’s [Formula: see text]-test with a 95% confidence level. In contrast, the MDD of conventional and the best one (no. 7) among all original 18 groups were 3.27[Formula: see text]mm and 2.93[Formula: see text]mm for 0.43[Formula: see text]mm and 0.41[Formula: see text]mm slit depths, respectively. Conclusion: The Taguchi analysis was found very lucrative for the design of imaging analysis in practical diagnosis. The indigenous line group gauge and hepatic phantom also proved to be suitable in simulating the human body in real hepatic carcinoma examination.

Funder

Central Taiwan University of Science and Technology

Taichung Armed Forces General Hospital in Taiwan

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3