QUANTITATIVE EVALUATION METHOD FOR TIBIOFIBULAR JOINT ALIGNMENT IN ANKLE OSTEOARTHRITIS BASED ON 3D BONE SIZE

Author:

Fujinuma Takuya1,Takemura Hiroshi1,Kosugi Shinichi2,Kurokawa Hiroaki3,Tanaka Yasuhito3,Tsuichihara Satoki1

Affiliation:

1. Department of Mechanical Engineering, Tokyo University of Science, 2641 Yamazaki, Noda-shi, Chiba 278-8510, Japan

2. Orthopedic Surgery, Nara Prefecture Western Medical Center, Nara, Japan

3. Orthopedic Surgery, Nara Medical University, Nara, Japan

Abstract

Purpose: A remedy for ankle osteoarthritis is artificial joint replacement surgery. By estimating the relative positional difference (alignment) between the bone before and after deformation, precise artificial joint replacement surgery can be performed. By using the estimated alignment, an artificial ankle joint can ensure high satisfaction with less pain and can perform necessary functions. Although bone alignment is currently estimated from X-rays and computed tomography (CT) images, it is difficult to measure three-dimensional (3D) data from two-dimensional (2D) images. Although 3D data can be estimated using a 2D–3D registration method, it requires capturing the bone images multiple times and imposing considerable burden on the patient. In this paper, we propose a method to estimate the 3D bone alignment based on the size of the bone using principal component analysis (PCA), which requires scanning only one data. Method: In the proposed method, PCA is used to create a 3D bone model based on the bone thickness, and the bone alignment is estimated by the Go-ICP algorithm. In this study, the images of the foot were captured using a CT device, and the 3D bone model was created by stacking CT images. For improving the accuracy of the alignment, a reference model based on the bone thickness was created using PCA. Subsequently, the bone was overlapped and the alignment was estimated. Result: For the evaluation of the accuracy of alignment in the proposed method, three types of methods were used to create a bone model. The proposed method was found to be the most accurate with respect to the true value in five of the six evaluation criteria. In addition, the alignment of the tibiofibular joint was evaluated using the proposed method. Regarding the displacement in the [Formula: see text]-axis direction, there were significant differences in both Stage 3B and Stage 4 compared with the healthy subjects. In addition, the magnitude of rotation in the [Formula: see text]-axis direction showed a significant difference in stage 3B as compared with a healthy subject. Conclusion: Using the proposed method, we have shown that bone alignment can be estimated three-dimensionally by scanning the bone data once only. In addition, by comparing with the reference model using PCA based on the thickness of the bone, the accuracy of alignment is improved as compared with the reference model, which is not based on the bone thickness.

Publisher

World Scientific Pub Co Pte Lt

Subject

Orthopedics and Sports Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3