DESIGN STRATEGY OF THREE-DIMENSIONAL PRINTED CAGES TO REDUCE IMPACT-INDUCED DEBRIS ALONG THE LOAD-TRANSFERRING PATH

Author:

Lin Shang-Chih1,Hsu Yu-Pao2,Yu Ching-Hsiao2,Chen Chun-Ming1,Chen Po-Quang3

Affiliation:

1. Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan, ROC

2. Department of Orthopedic Surgery, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan, Taiwan, ROC

3. Department of Orthopedic Surgery, Hospital of National Taiwan University, Taipei, Taiwan, ROC

Abstract

Peri-implant debris certainly lead to osteolysis, necrosis, pseudotumor formation, tissue granulation, fibrous capsule contractions, and even implant failure. For the three-dimensional (3D) printed cage, impaction during cage insertion is one of the most potential sources of fracture debris. A finite-element study was carried out to reduce the impact-induced debris of the 3D-printed cage. This study focused on the design strategy of solid and cellular structures along the load-transferring path. Using the finite-element method, the cellular structure of the transforaminal lumbar interbody fusion (TLIF) cage was systematically modified in the following four variations: a noncellular cage (NC), a fully cellular (FC) cage, a solid cage with a cellular structure in the middle concave (MC) zone, and a strengthened cage (SC) in the MC zone. Three comparison indices were considered: the stresses at the cage-instrument interfaces, in the MC zone, and along the specific load-transferring path. The NC and FC were the least and most highly stressed variations at the cage-instrument interfaces and in the MC zone, respectively. Along the entirely load-transferring path, the FC was still the most highly stressed variation. It showed a higher risk of stress fracture for the FC cage. For the MC and SC, the MC zone was consistently more stressed than the directly impacted zone. The further strengthened design of the SC had a lower peak stress (approximately 29.2%) in the MC zone compared with the MC. Prior to 3D printing, the load-transferring path from the cage-instrument interfaces to the cage-tissue interfaces should be determined. The cage-instrument interfaces should be printed as a solid structure to avoid impact-induced fracture. The other stress-concentrated zones should be cautiously designed to optimize the coexistence strategy of the solid and cellular structures.

Publisher

World Scientific Pub Co Pte Lt

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3