NON-INVASIVE TECHNIQUE FOR IN VIVO HUMAN EAR CANAL VOLUME MEASUREMENT

Author:

YU JEN-FANG12,TSAI GO-LONG34,FAN CHUNG-CHIEH342,CHEN CHING-I5,CHENG CHIA-CHI6,CHEN CHENG-CHUNG2

Affiliation:

1. Graduate Institute of Medical Mechatronics, Chang Gung University, Taoyuan, Taiwan

2. Taiouan Interdisciplinary Otolaryngology Laboratory, Chang Gung University, Taoyuan, Taiwan

3. Department of Vehicle Engineering, National Taipei University of Technology, Taipei, Taiwan

4. Institute of Mechatronic Engineering, National Taipei University of Technology, Taipei, Taiwan

5. Department of Mechanical Engineering, Chung Hwa University, Hsinchu, Taiwan

6. Department of Otolaryngology-Head and Neck Surgery, Chang Gung Memorial Hospital and Chang Gung University, Taoyuan, Taiwan

Abstract

This prospective study is to develop a new non-invasive in vivo technique for the measurement of the human external auditory canal (EAC) volume using high resolution computed tomography (HRCT). Eighteen ears of nine male volunteers, with an age range of 20–30, were measured. The EAC volume was measured using three different methods: tympanometry, water injection, and HRCT. Two dimensional image slices of the EAC, in vivo, were obtained from the raw HRCT data. Each 2D CT image slice was composed of 512 × 512 pixels, with a 0.5 mm slice thickness, and a 0.175 × 0.175 × 0.5 mm3 voxel size. HRCT images were processed with Amira® software (Visage Imaging, Inc., San Diego, USA). Three-dimensional images of the EAC were reconstructed using an unconstrained smoothing mode. The resulting volume of the 3D model of the EAC was calculated using a voxel gate stacked tool. Using tympanometry, the mean measured EAC volume, averaged over all ears, was 766.66 mm3 (Standard Deviation, SD = 194.03 mm3). Using water injection, the mean measured EAC volume was 1102.77mm3 (SD = 121.60 mm3). Using HRCT, the mean measured EAC volume was 1082.22 mm3 (SD = 119.63 mm3). As evident from the SD values, variability was greater in the tympanometry group than in the water injection and HRCT groups. This study successfully developed a new technique to measure the EAC volume using HRCT imaging. This non-invasive technique for in vivo EAC volume measurement was less variable than tympanometry, and avoided the intrusive aspect of measurement by water injection. The technique allows effective, non-invasive assessment of the EAC volume pre-canalplasty, providing a predictor of EAC volume post-canalplasty.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3