Abstract

Background: Adequate research is not reported so far to underline the influence of commonly used polycentric knee joints on gait performance of subjects with trans-femoral amputation. Objective: The intent of this investigation is to analyze prosthetic gait of unilateral traumatic trans-femoral amputees with polycentric four-bar linkage knee and compare it with normal subjects for evaluating any asymmetry in gait performance. Methods: Objective three-dimensional gait analysis of 15 subjects [mean (age): 36.4 (10.7) years] were performed in gait lab through force plate and optoelectronic devices to measure temporal-spatial parameters, kinematic and kinetic performances. Gait patterns of amputees were compared with those of 15 individuals with normal gait to analyze distinct functionalities of existing polycentric knee. Results: Asymmetry in gait was observed between amputees and normal subjects for all variables concerned ([Formula: see text]). Amputee gait was with significantly lesser velocity, cadence with shorter step and stride length. There was significantly less hip, knee and pelvic motions, however, pelvic obliquity and rotation did not show significant difference from the normal subjects. The vertical component of the ground reaction force differed significantly between prosthetic and intact limb [49.7 (8.5)% and 90.4 (7.4)% body weight] and also from normal subjects [107.5 (2.4)% body weight] during stance ([Formula: see text]). Interpretation and Conclusion: This difference may be attributed to nonproportionate loading of limbs and mechanical adaptations for counteracting deficiencies of prosthetic side. This study will help to explain gait asymmetry in trans-femoral amputees and to identify underlying mechanisms to enhance the quality of the existing design of prosthetic knee through optimizing design parameters and utilizing appropriate materials.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3