OPTIMUM FORCE SYSTEM FOR EN-MASSE RETRACTION OF SIX MAXILLARY ANTERIOR TEETH IN LABIAL ORTHODONTICS

Author:

THOTE ABHISHEK M.1ORCID,UDDANWADIKER RASHMI V.2,SHARMA KRISHNA3,SHRIVASTAVA SUNITA4,REDDY VENKATESWAR5

Affiliation:

1. School of Mechanical Engineering, MIT-World Peace University, Pune, Maharashtra, India

2. Department of Mechanical Engineering, Visvesvaraya National Institute of Technology, Nagpur, Maharashtra, India

3. Private Practice, Toothart Clinic, Nagpur, Maharashtra, India

4. Department of Orthodontics, Sharad Pawar Dental College, Wardha, Maharashtra, India

5. Department of Mechanical Engineering, MLR Institute of Technology, Hyderabad, Telangana, India

Abstract

The orthodontists generally do not recommend application of force system above the archwire level owing to additional attachments and patient’s discomfort. Hence, the present research study focusses on application of retraction force system at the archwire level. The objective of this study is to specify an optimum combination of archwire and bracket slot size for en-masse (simultaneous) parallel retraction of six maxillary anterior teeth in labial orthodontics (LaO). In this research study, the concept (theoretical) model has been developed based on simple principles of mechanics to estimate the torque generated by different sizes of archwire in bracket slots. Based on torque value, retraction force developed by each combination of archwire and slot size was determined and compared with required retraction force of 150 gram-force on each side of sagittal plane. For combination of [Formula: see text] inch stalinless steel SS archwire and 0.022 inch SS bracket slot, magnitude of computed retraction force matched closely with aforementioned required force than other combinations and hence, it is recommended in the present research study. The validation of selected combination of archwire and bracket slot size was done successfully by in vivo (clinical) experimentation on three patients. Thus, it proves that the aforementioned combination of archwire and bracket slot size is more suitable than others for retraction force system applied at archwire level.

Publisher

World Scientific Pub Co Pte Lt

Subject

Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3