Minimally Invasive Method of Measuring Anti-Müllerian Hormone Level in Dried Blood Spots of Indonesian Infertile Population

Author:

Sini Ivan12ORCID,Handayani Nining2ORCID,Tjahjadi Ricky3ORCID,Wulandari Tri Aprilliana2ORCID,Afadlal Szeifoul12ORCID,Polim Arie Adrianus124ORCID,Sirait Batara125ORCID,Suheimi Irham26ORCID,Boediono Arief127ORCID

Affiliation:

1. Morula IVF Jakarta Clinic, Jakarta, Indonesia

2. IRSI Research and Training Centre, Jakarta, Indonesia

3. Diagnos Laboratory, Jakarta, Indonesia

4. Department of Obstetrics and Gynecology, School of Medicine and Health Sciences, Atmajaya Catholic University of Indonesia, Jakarta, Indonesia

5. Department of Obstetrics and Gynaecology, Faculty of Medicine Universitas Kristen Indonesia, Jakarta, Indonesia

6. STIKes PMC, Pekanbaru, Indonesia

7. Department of Anatomy, Physiology and Pharmacology, IPB University, Bogor, Indonesia

Abstract

This study aims to evaluate the certainty of anti-Müllerian hormone (AMH) levels in dried blood spots (DBS) compared to serum AMH. A total of 109 infertile women who planned to undergo their controlled ovarian stimulation cycle were recruited. Serum and DBS samples were collected from each patient for the quantification of AMH levels. Serum AMH was measured with an automated clinical chemistry assay (Roche) while DBS AMH was measured using the Ansh Labs DBS AMH ELISA reagent kit. Mean AMH level in DBS was [Formula: see text][Formula: see text]ng/mL, which ranged from 0.01 to 17.3[Formula: see text]ng/mL, while the mean AMH in serum samples was [Formula: see text][Formula: see text]ng/mL (0.01–10.8[Formula: see text]ng/mL). Comparable accuracy for low AMH quantification was observed between the two methods over basal antral follicle counts (AFC) as a clinical comparator (AUC 86%, cutoff [Formula: see text][Formula: see text]ng/mL, [Formula: see text], [Formula: see text] vs. 85%, cutoff [Formula: see text][Formula: see text]ng/mL, [Formula: see text], [Formula: see text], respectively for DBS and serum sample). Likewise, DBS AMH achieved high concordance for low AMH discrimination in comparison to serum AMH method (AUC 99% vs. 93%, respectively). A strong linear Spearman regression ([Formula: see text], [Formula: see text]) and sufficient agreement (94.5%, mean difference of −1.6, 2.7 to −5.9) was demonstrated among studied groups with mathematical Passing and Bablok regression equation of [Formula: see text]. The confidence interval of intercept (−0.12, 95% CI [−0.29 to −0.01]) and slope (1.80, 95% CI [1.66–1.94]) indicated a constant and proportional difference between the two methods but it was not significant ([Formula: see text]). AMH measurement in DBS could be useful as an alternative approach to screening ovarian reserve through a more convenient remote sample collection.

Publisher

World Scientific Pub Co Pte Ltd

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3