POLOCALC: A Novel Method to Measure the Absolute Polarization Orientation of the Cosmic Microwave Background

Author:

Nati Federico1ORCID,Devlin Mark J.1,Gerbino Martina2,Johnson Bradley R.3,Keating Brian4,Pagano Luca5,Teply Grant4

Affiliation:

1. Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, 19104 PA, USA

2. The Oskar Klein Centre for Cosmoparticle Physics, Department of Physics, Stockholm University, SE-106 91 Stockholm, Sweden

3. Department of Physics, Columbia University, New York, NY 10027, USA

4. Department of Physics, University of California, San Diego, CA 92093-0424, USA

5. Institut d’Astrophysique Spatiale, CNRS, Univ. Paris-Sud, Université Paris-Saclay, Bât. 121, 91405 Orsay cedex, France

Abstract

We describe a novel method to measure the absolute orientation of the polarization plane of the Cosmic Microwave Background (CMB) photons with arcsecond accuracy, enabling unprecedented measurements for cosmology and fundamental physics. Existing and planned CMB polarization instruments looking for primordial B-mode signals need an independent, experimental method for systematics control on the absolute polarization orientation. The lack of such a method limits the accuracy of the detection of inflationary gravitational waves, the constraining power on the neutrino sector through measurements of gravitational lensing of the CMB, the possibility of detecting Cosmic Birefringence (CB), and the ability to measure primordial magnetic fields. Sky signals used for calibration and direct measurements of the detector orientation cannot provide an accuracy better than 1[Formula: see text]. Self-calibration methods provide better accuracy, but may be affected by foreground signals and rely heavily on model assumptions, losing constraining power on fundamental processes, like CB, Faraday Rotation and chiral gravity models. The POLarization Orientation CALibrator for Cosmology, POLOCALC, will dramatically improve instrumental accuracy by means of an artificial calibration source flying on high-altitude balloons and aerial drones. Polarization angle calibration requires observation of a well-characterized distant source at high elevation angles. A balloon-borne calibrator will provide a source in the far field of larger telescopes, while an aerial drone can be used for tests and smaller polarimeters. POLOCALC will also allow a unique method to measure the telescopes’ polarized beam. Even a two-hour balloon flight will allow enough time to perform polarization angle calibration and polarized beam function measurements. The source will make use of both narrow and broadband microwave emitters between 40[Formula: see text]GHz and 150[Formula: see text]GHz coupled to precise polarizing filters. The orientation of the source polarization plane will be registered to absolute celestial coordinates by star cameras and gyroscopes with arcsecond accuracy. This project can become a rung in the calibration ladder for the field: any existing or future CMB polarization experiment observing our novel polarization calibrator will enable measurements of the polarization angle for each detector with respect to absolute sky coordinates.

Publisher

World Scientific Pub Co Pte Lt

Subject

Astronomy and Astrophysics,Instrumentation

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献